This specification covers requirements for the methods of application and finishing of gypsum board. Construction details for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. Gypsum board assembly shall conform to acoustical tests of the specification where sound control is required. Moreover, gypsum assembly shall conform to framing size, fasteners spacing, ventilation, substrate, surface preparation, cutting, and installation application as indicated in the specification. Materials categorized under this specification include: gypsum boards, gypsum wallboards, gypsum backing board and coreboard, water-resistant gypsum backing board, exterior gypsum soffit board, and gypsum ceiling board. Finishing materials include: compounds, joint tape, fasteners, nails, screws, and staples. A fire test of assemblies shall be conducted to determine a fire resistance rating required for gypsum board assembly. Gypsum board shall be cut by scoring and breaking or by sawing, working from the face side. Masonry or concrete walls shall be dry, free of dust, oil, or form release agents, protrusions or voids, or foreign matter that inhibit bond for adhesively applied gypsum board. All materials shall be kept dry. Where gypsum board is stored outside, it shall be off the ground, properly supported on a level platform and fully protected from the weather or direct sunlight exposure.
 Scope
 1.1  This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories to interior walls and ceilings and to exterior soffits.
 1.2  Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.
 1.2.1  Where this specification is more stringent (size or thickness of framing: size and spacing of fasteners) than the fire-rated construction, this specification shall govern.
 1.3  Where sound control is required for a gypsum board assembly, details of construction shall be in accordance with reports of acoustical tests of assemblies that have met the required acoustical values.
 1.4  Unheated spaces above gypsum board ceilings shall be properly ventilated (see Appendix X2 ).
 1.5  The various application systems are located in the following sections:
 I
 Application of Single-ply Gypsum Board to Wood Framing Members
 8
 II
 Application of Two-ply Gypsum Board to Wood Framing Members
 9
 III
 Application of Gypsum Board by Adhesive Nail-on to Wood Framing      Members
 10
 IV
 Semi-solid Gypsum Board Partitions
 11
 V
 Solid Gypsum Board Partitions
 12
 VI
 Application of Gypsum Board with Adhesives to Interior Masonry or      Concrete Walls
 13
 VII
 Application of Gypsum Board to Rigid Foam Insulation
 14
 VIII
 Application of Gypsum Board to Steel Framing and Furring
 15
 IX
 Arches and Bending Radii
 16
 X
 Application of Gypsum Board to Receive Tile by Adhesive Application
 17
 XI
 Application of Exterior Gypsum Soffit Board or Other Gypsum Board for Use in Exterior Soffits
 18
 XII
 Floating Interior Angles
 19
 XIII
 Control (Expansion) Joints
 20
 XIV
 Foil-backed Gypsum Board
 21
 XV
 Application of Vinyl Faced Gypsum Board
 22
 1.6  The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
 1.7  The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
 1.8   The following precautionary caveat pertains only to Sections 6 – 26 . This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
 For specific precautionary statements, see 4.1.1 , 4.1.2 , and 24.5 .
 1.9   This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ASTM C840-25 PDF

ASTM C840-25 PDF

$52.00 $104.00