BS 6387-2013 PDF

BS 6387-2013 PDF

Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions

$147.32 $294.64 -50%
Publisher
isbn 9780580810466
Product Code: BS 6387
Stock In Stock
Published: 12/31/2013
Number of Pages: 24
File Size: 1 file, 780 KB

Available Options

Product Description

Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 December 2013. It was prepared by Subcommittee GEL/20/18, Fire testing, under the authority of Technical Committee GEL/20, Electric cables. A list of organizations represented on these committees can be obtained on request to their secretary. Supersession This British Standard supersedes BS 6387:1994, which is withdrawn.

Information about this document: This is a full revision of the standard, which now gives only a test method for fire resistance characteristics of cables. Physical and electrical tests and their relevant requirements are now given in the appropriate product standards. Other test methods for the fire resistance of cables have been developed since the previous revision of BS 6387. These include BS 8434 and BS 8491, catering for specific applications, installations and end-user markets. The test method given in this British Standard consists of three component protocols, designated C, W and Z. These are technically unchanged from the previous edition. Previous editions of BS 6387 have included categories based on other protocols (A, B, S, X and Y). These are now regarded as obsolete. When separate test pieces from the same sample of cable are tested to each of these three protocols, these together comprise the full test. When the requirements of each one of the protocols are met, the cable may be designated as “category CWZ”. In detail: a) Protocol C subjects the cable under test to a flame via direct impingement corresponding to a temperature attack of 950 °C ±40 °C. b) Protocol W subjects the cable under test to a flame via direct impingement corresponding to a temperature attack of 650 °C ±40 °C with direct application of water simulating a sprinkler system. c) Protocol Z subjects the cable under test to a flame via direct impingement corresponding to a temperature attack of 950 °C ±40 °C with indirect application of mechanical shock. Product standards might refer to only one of the protocols C or W or Z in, respectively, Clauses 6, 7 or 8 but, in such cases, may not use the designation “Category CWZ”. It is emphasized that fire tests do not assess a fire hazard, nor can the results of fire tests alone guarantee safety. They only provide information to assist in the assessment of the suitability of a cable for a given application. Hazard warnings WARNING. This British Standard calls for the use of substances and/or procedures that can be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage. The test methods given in this British Standard might involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risks of shock, burning, fire and explosion that might be involved, and against any noxious fumes that might be produced.

Use of this document: It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its methods are expressed as a set of instructions, a description, or in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element.

Scope: This British Standard gives a test method for resistance to fire of cables required to maintain circuit integrity under fire conditions. It is applicable to cables of rated voltage not exceeding 600/1 000 V and of overall diameter less than or equal to 20 mm. The test given in this British Standard is applicable to cables having two or more insulated conductors, whether or not the cables incorporate other metallic elements such as armour, screen or circuit protective conductor. The test is also applicable to cables having one insulated conductor provided that the cable incorporates at least one other metallic element. The test is not applicable to cables having one insulated conductor but no other metallic element.

Contents:

  • Foreword
  • Scope
  • Bibliography