BS 9992-2020 PDF
Fire safety in the design, management and use of rail infrastructure. Code of practice
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ACI-American Concrete Institute
- ANSI-American National Standards Institute
- API-American Petroleum Institute
- AS-Standards Australia
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASME-ASME International
- ASTM-ASTM International
- AWS-American Welding Society
- AWWA-American Water Works Association
- BS-BSI Group
- ISO-International Organization for Standardization
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- SAE-SAE International
- UL-Underwriters Laboratories
- UNE-Asociación Española de Normalización
Your shopping cart is empty!
Product Description
Fire safety in the design, management and use of rail infrastructure. Code of practice
Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 April 2020. It was prepared by Technical Committee FSH/14, Fire precautions in buildings. A list of organizations represented on this committee can be obtained on request to its secretary. Relationship with other publications The British Standard is intended to be read in conjunction with BS 9999:2017.
Information about this document: The British Standard is intended to be used by: railway owners, operators and infrastructure managers; train operating companies (TOCs) – safety managers, station and tunnel managers and engineers; design houses (single and multi‑disciplinary) – project managers, project engineers and fire safety engineers; architects of railway infrastructure; building and construction contractors; system design contractors (engineers); suppliers and installers of fire protection systems in railway infrastructure (fire detection and fire alarm systems, fire suppression and extinguishing systems, smoke control, pressurization and extract systems, fire‑resisting structures and separating elements, materials with fire performance requirements); regulators; and maintainers. This British Standard provides recommendations and guidance on the provision of measures to control or mitigate the effects of fire. The primary objective is to ensure that an adequate standard of life safety can be achieved in the event of fire in the premises. A secondary objective is to provide a level of protection for property, the operation of the railway and businesses against the impact of fire, e.g. in close proximity to other premises or as part of the same premises or complex. These objectives can also have the effect of assisting the fire and rescue service and/or of providing environmental protection. There are references throughout this British Standard to occupant safety, firefighter safety, and business and property protection, to draw attention to the different issues these could raise. It is, however, important to be aware that provisions solely for life safety are unlikely to provide the full level of protection for buildings and property in a fully developed fire scenario. This British Standard complements BS 9999 and varies from it only where appropriate to support the particular ways in which railway infrastructure is constructed or operated. Where recommendations are not explicitly included, then the default is that BS 9999 be referred to for relevant guidance. A fire safety engineering approach as detailed in BS 7974 might be more appropriate in the design of some complex railway premises. BRITISH STANDARD This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Use of this document: As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this British Standard is expected to be able to justify any course of action that deviates from its recommendations. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced.
Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. The word “should” is used to express recommendations of this standard. The word “may” is used in the text to express permissibility, e.g. as an alternative to the primary recommendation of the clause. The word “can” is used to express possibility, e.g. a consequence of an action or an event. Notes and commentaries are provided throughout the text of this standard. Notes give references and additional information that are important but do not form part of the recommendations. Commentaries give background information. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).
Scope: This British Standard gives recommendations and guidance on the design, management and use of railway buildings and the permanent way to achieve reasonable standards of fire safety for all people in and around rail infrastructure (railways and guided systems). It covers: stations (surface, sub‑surface and enclosed); platforms; tunnels; viaducts; elevated rail; train care depots and maintenance facilities; training facilities; sidings; signalling/control facilities; and ancillary buildings. This British Standard is primarily intended for life safety but also gives guidance on protection of property, business and operations. This British Standard is applicable to the design of new premises, and to material alterations, extensions and material change of use of existing premises. This British Standard does not cover fire safety of rolling stock, or fire safety design strategies for extreme events such as terrorist actions. 4 © THE BRITISH STANDARDS INSTITUTION 2020 – ALL RIGHTS RESERVED