Application of fire safety engineering principles to the design of buildings-Fire and rescue service intervention (Sub system 5)
Publishing information: This Published Document is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 November 2014. It was prepared by Technical Committee FSH/24, Fire safety engineering. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession PD 7974-5:2014+A1:2020 supersedes PD 7974‑5:2014, which is withdrawn. Relationship with other publications This Published Document takes information on building characteristics and the design fire from the qualitative design review (QDR) together with the time of fire service notification from sub‑system 4 (PD 7974‑4) and the time of evacuation from sub‑system 6 (PD 7974‑6). It provides information on the effect of fire service activities on the growth of the fire, which is used by sub‑system 1 (PD 7974‑1). PD 7974‑5 is part of the PD 7974 series. Other documents in the series are: Part 1: Initiation and development of fire within the enclosure of origin (Sub‑system 1); Part 2: Spread of smoke and toxic gases within and beyond the enclosure of origin (Sub‑system 2); Part 3: Structural response and fire spread beyond the enclosure of origin (Sub‑system 3); Part 4: Detection of fire and activation of fire protection systems (Sub‑system 4); Part 6: Human factors – Life safety strategies – Occupant evacuation, behaviour and condition (Sub‑system 6); Part 7: Probabilistic risk assessment. These Published Documents are intended to be used in support of BS 7974. Where appropriate, references to relevant standards are provided in order to assist the reader in understanding the design methodologies presented and to compare different approaches or sources of data. It is therefore important that PD 7974-5 is not used in isolation and reference is made to the relevant standards, particularly in relation to additional notes and subclauses describing its application.
Information about this document: This is an amendment of the Published Document and introduces updated and new guidance on the relationship between building design and fire and rescue service operating procedures. The guidance provided within this Published Document may be considered incomplete at this time, particularly requiring a fundamental review of firefighting access provisions. There are a number of matters under recent national regulatory consultation and review. These include (but are not limited to): a) the maximum permitted building heights denoting a range of firefighting access measures in both new and refurbished buildings; b) the physiological limitations placed on firefighters, firefighter safety particularly in extended corridors and single stair buildings; PUBLISHED DOCUMENT PD 7974-5:2014+A1:2020 c) the adequate provision of modern firefighting lifts; d) external wall hazards; e) wayfinding; f) mass evacuation of tall residential and other high-rise buildings; g) evacuation alert systems; h) sprinkler provisions; i) basement ventilation for firefighting access; j) smoke control provisions; k) specific materials used in construction; and l) along with a range other matters that may be subject to the outcomes of ongoing national review. All of these issues directly impact on existing fire and rescue service operating procedures and will therefore be dealt with in a future revision of this Published Document. Users of the current edition of this Published Document need to ensure that the local fire and rescue service is consulted as a stakeholder, as part of the Qualitative Design Review process, where a fire safety engineering approach to access and facilities for the fire service is proposed. Text introduced by or altered by Amendment No. 1 is indicated in the text by tags . Minor editorial corrections are not tagged. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Use of this document: As a guide, this Published Document takes the form of guidance and recommendations. It should not be quoted as if it were a specification or a code of practice and claims of compliance cannot be made to it. This publication is not regarded as a British Standard.
Presentational conventions: The guidance in this Published Document is presented in roman (i.e. upright) type. Any recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element.