BS PD ISO/TR 37137-2014 PDF

BS PD ISO/TR 37137-2014 PDF

Cardiovascular biological evaluation of medical devices. Guidance for absorbable implants

$147.32 $294.64 -50%
Publisher
isbn 9780580843525
Product Code: BS PD ISO/TR 37137
Stock In Stock
Published: 06/30/2014
Number of Pages: 26
File Size: 1 file, 1 MB

Available Options

Product Description

Cardiovascular biological evaluation of medical devices. Guidance for absorbable implants

Scope: The objective of this Technical Report is to provide interim Part-by-Part guidance on potential adjustments to various test methods within the 10993 series to account for the intentional release of soluble components or degradation products from absorbable medical devices. The content is intended to add clarity and present potentially acceptable approaches for reducing the possibility of erroneous or misleading results due to the nature of the absorbable material. All suggestions should be considered as preliminary and subject to change, with final dispositions implemented through direct modification to the respective parts of ISO 10993. Thus, interim adoption of any of the described adjustments requires an accompanying written justification. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 absorb action of a non-endogenous (foreign) material or substance passing through or being assimilated by cells and/or tissue over time 2.2 degradation product any intermediate or final result from the physical, metabolic, and/or chemical decomposition of a material or substance 2.3 degrade to physically, metabolically, and/or chemically decompose a material or substance 2.4 leachable substances that can be released from a medical device or material during clinical use Note 1 to entry: In absorbable devices, leachables can be substances released from the as-manufactured product or substances generated and released as a consequence of its degradation (i.e degradation products). [SOURCE: ISO 10993‑12:2012, 3.10 modified — Note 1 to entry has been added.] 3 General considerations Biological evaluation is the assessment of the ability of a device, device component, or a material to be present in the body without creating an adverse systemic impact and/or local effect on the surrounding cells and/or tissue. Biological evaluation of an absorbable material should be conducted in accordance with ISO 10993

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD ISO/TR 37137-2014 PDF

BS PD ISO/TR 37137-2014 PDF

$147.32 $294.64