IEC TS 63342-2022 PDF
C-Si photovoltaic (PV) modules-Light and elevated temperature induced degradation (LETID) test-Detection
- 3A-3-A Sanitary Standards
- 9000-9000 Store
- A3-Association for Advancing Automation
- A4A-Airlines for America
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ABCB-Australian Building Codes Board
- ABMA-American Bearing Manufacturers Association
- ABMA-BOILER-American Boiler Manufacturers Association
- ACC-American Chemistry Council
- ACGIH-American Conference of Governmental Industrial Hygienists
- ACI-American Concrete Institute
- AEIC-Association of Edison Illuminating Companies
- AES-Audio Engineering Society
- AFCEN-French Association
- AGA-American Gas Association
- AGMA-American Gear Manufacturers Association
- AHAM-Association of Home Appliance Manufacturers
- AHP-American Herbal Pharmacopoeia
- AHRI-Air-Conditioning, Heating, and Refrigeration Institute (formerly ARI)
- AIA-Aerospace Industries Association
- AIAA-American Institute of Aeronautics and Astronautics
- AICHE-American Institute of Chemical Engineers
- AIHA-American Industrial Hygiene Association
- AISC-American Institute of Steel Construction
- ALI-American Ladder Institute
- ALPEMA-Aluminium Plate-Fin Heat Exchanger Manufacturers' Association
- AMCA-Air Movement and Control Association
- ANS-American Nuclear Society
- ANSI-American National Standards Institute
- ANSI/ANSLG-American National Standards Institute / American National Standard Lighting Group
- ANSI/NEMA-American National Standards Institute / National Electrical Manufacturers Association
- ANSI/TCNA-Tile Council of North America, Inc.
- ANSI/UAMA-Unified Abrasives Manufacturers' Association
- API-American Petroleum Institute
- APWA-American Public Works Association
- AREMA-American Railway Engineering and Maintenance-of-Way Association
- ARINC-ARINC Industry Activities
- ARMY-United States Army Publication
- AS-Standards Australia
- ASA-Acoustical Society of America Standards
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASD-STAN prEN-ASD-STAN Standardization
- ASHE-American Society for Healthcare Engineering
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASIS-ASIS International
- ASM-ASM International
- ASME-ASME International
- ASNT-The American Society for Nondestructive Testing
- ASQ-American Society for Quality
- ASSE (Plumbing)-American Society of Sanitary Engineering
- ATIS-The Alliance for Telecommunications Industry Solutions
- ASTM-ASTM International
- AVIXA-Audiovisual and Integrated Experience Association
- AWC-American Wood Council
- AWI-Architectural Woodwork Institute
- AWS-American Welding Society
- AWWA-American Water Works Association
- AWPA-American Wood Protection Association
- B11-B11 Standards, Inc.
- BHMA-Builders Hardware Manufacturers Association
- BICSI-BICSI, A Telecommunications Association
- BioWorld-Thomson Reuters BioWorld
- BMI-Battelle - Metallic Materials Properties Development and Standardization (MMPDS)
- BS-BSI Group
- CAN/CGSB-Canadian General Standards Board
- CAN/ULC-Underwriters Laboratories of Canada
- CEI-Comitato Elettrotecnico Italiano
- CFR-Code of Federal Regulations
- CGA-Compressed Gas Association
- CIE-Commission Internationale de L'Eclairage
- CII-Construction Industry Institute
- CISPR-International Special Committee on Radio Interference
- CLSI-Clinical and Laboratory Standards Institute
- CMAA-Crane Manufacturers Association of America, Inc.
- CRANE-Crane Co.
- CRSI-Concrete Reinforcing Steel Institute
- CSA-Canadian Standards Association
- CTA-Consumer Technology Association (Formerly CEA)
- CTI-Cooling Technology Institute
- DANSK-Dansk Standard
- DID-Data Item Description
- DIN-Deutsches Institut Fur Normung E.V. (German National Standard)
- DNV-DNV
- DOD-Department of Defense
- DOXPUB-Doxpub, Inc.
- DVS-DEUTSCHER VERBAND FÜR SCHWEISSEN UND VERWANDTE VERFAHREN E.V.
- ECIA-Electronic Components Industry Association
- EEC-European Union Directives
- EEMUA-Engineering Equipment and Materials Users Association
- ESD-EOS/ESD Association, Inc.
- ETSI-European Telecommunications Standards Institute
- FCI-Fluid Controls Institute
- ISO-International Organization for Standardization
- ISO/IEC/IEEE-International Organization for Standardization / International Electrotechnical Commission / Institute of Electrical and Electronics Engineers
- ISPE-International Society for Pharmaceutical Engineering
- FED-Federal Specifications and Standards
- ISTA-International Safe Transit Association
- ISUZU-Isuzu Motors Ltd.
- FM Approvals-FM Approvals
- JEDEC-JEDEC Solid State Technology Association
- JSA-Japanese Standards Association (JIS Standards)
- LIA-Laser Institute of America
- FORD-Ford Motor Company
- MBMA-Metal Building Manufacturers Association
- MCGRAW-HILL-McGraw-Hill Publishing Company
- FRPI-Fiberglass Reinforced Plastics Institute, Inc.
- MIL-Military Specifications and Standards
- MPIF-Metal Powder Industries Federation
- MPMA-Motion + Power Manufacturers Alliance (MPMA) (Formerly AGMA & ABMA)
- GMW-General Motors Worldwide
- MSS-Manufacturers Standardization Society of the Valve and Fittings Industry
- NAAMM-National Association of Architectural Metal Manufacturers
- GPA-GPA Midstream Association
- NACE-National Association of Corrosion Engineers
- NADCA-National Air Duct Cleaners Association
- NAS-Aerospace Industries Association - National Aerospace Standard
- HEI-Heat Exchange Institute
- NASA-National Aeronautics and Space Administration
- NBBI-The National Board of Boiler and Pressure Vessel Inspectors
- NCSL-National Conference of Standards Laboratories International
- HFES-Human Factors and Ergonomics Society
- NECA-National Electrical Contractors Association
- RTCA-RTCA, Inc.
- HI-Hydraulic Institute
- NEMA-National Electrical Manufacturers Association
- NETA-InterNational Electrical Testing Association
- NFPA (Fire)-National Fire Protection Association
- HIR-H.I.R. Technical Services
- NFPA (Fluid)-National Fluid Power Association
- NFSI-National Floor Safety Institute
- HPS-Health Physics Society
- NGA-National Glass Association
- NISO-National Information Standards Organization
- NORSOK-NORSOK
- I3A-International Imaging Industry Association
- NRC-National Research Council Canada
- NSC-Natural Stone Council
- IADC-International Association of Drilling Contractors
- NSF-NSF International
- NZS-Standards New Zealand
- OPEI-Outdoor Power Equipment Institute
- IAPMO-International Association of Plumbing and Mechanical Officials
- PCI-Precast/Prestressed Concrete Institute
- PDA-Parenteral Drug Association
- IATA-International Air Transport Association
- PEI-Petroleum Equipment Institute
- PFI-Pipe Fabrication Institute
- PIA-Parachute Industry Association
- ICAO-International Civil Aviation Organization
- PIP-Process Industry Practices
- PPI-Plastics Pipe Institute
- ICC-International Code Council
- PTI-Post-Tensioning Institute
- ICEA-Insulated Cable Engineers Association
- ICML-International Council for Machinery Lubrication
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- IES-Illuminating Engineering Society
- IEST-Institute of Environmental Sciences and Technology
- IFI-Industrial Fasteners Institute
- IICRC-Institute of Inspection, Cleaning and Restoration Certification
- INCITS-InterNational Committee for Information Technology Standards (formerly NCITS)
- INTERN-International Motors, LLC (Formerly NAVISTAR)
- IPC-IPC by Global Electronics Association
- ISA-International Society of Automation
- ISEA-International Safety Equipment Association
- SAE-SAE International
- SAIA-Scaffold & Access Industry Association
- SCTE-Society of Cable Telecommunication Engineers
- SDI-Steel Door Institute
- SES-The Society for Standards Professionals
- SIA-Security Industry Association
- SJI-Steel Joist Institute
- SMACNA-Sheet Metal and Air Conditioning Contractors' National Association
- SME-Society of Manufacturing Engineers
- SMPTE-Society of Motion Picture and Television Engineers
- SN EN-Standards Norway EN
- SPC-Standards Press of China
- SPI-Society of the Plastics Industry
- SSPC-Society for Protective Coatings
- STI/SPFA-Steel Tank Institute/Steel Plate Fabricators Association
- TAPPI-Technical Association of the Pulp and Paper Industry
- TCIA-Tree Care Industry Association
- TEMA-Tubular Exchanger Manufacturers Association
- THHILL-TH Hill Associates, Inc.
- TIA-Telecommunications Industry Association
- TMS-The Masonry Society
- UL-Underwriters Laboratories
- ULC-Underwriters Laboratories of Canada
- UNE-Asociación Española de Normalización
- WILEY-John Wiley and Sons
- WRC-Welding Research Council, Inc.
- WSPC-World Scientific Publishing Co.
- X9-Accredited Standards Committee X9 Incorporated
Your shopping cart is empty!
Product Description
C-Si photovoltaic (PV) modules – Light and elevated temperature induced degradation (LETID) test – Detection
Scope: This document is designed to assess the effect of light induced degradation at elevated temperatures (LETID) by application of electrical current at higher temperatures. LETID is activated by excess carriers caused either through illumination or injection of electrical current at temperatures above 50 °C. In fielded conditions, LETID develops over the course of several months up to years as opposed to days for Boron Oxygen (B-O) degradation. The degradation phase is followed by an even slower recovery phase that develops over a significantly longer time scale. In this document, only the current injection approach for the detection of LETID is addressed. This document does not address the B-O and Iron Boron (Fe-B) related degradation phenomena, which already occur at room temperatures under the presence of light and on much faster time scales. B-O defects may influence the results, and this document attempts to separate them by application of certain procedures. However, it is noted that the separation may not be perfect. Fe-B effects are excluded by introduction of waiting times before power determination. The proposed test procedure can reveal sample sensitivity to LETID degradation mechanisms, but it does not provide an exact measure of field observable degradation. The magnitude and time scale of degradation seen in the field depends on climate and the module technology. In this document LETID testing is done via current injection as this is a simple method in terms of the test equipment required. This allows for better control over conditions compared to application of light and thus ensures comparability between different labs. Application of light with equivalent conditions (i.e. same temperature and excess carrier density/ injection level) will yield comparable results. The stress conditions in this document differ in injection level from the test method for cells described in IEC TS 63202-4. Whereas IEC TS 63202-4 aims at providing a quick quality check for a known cell that can be used in outgoing or incoming inspection of a specific product, the procedures in this document aim at providing a general product independent test method for LETID detection i
Contents:
- FOREWORD
- Scope


