Microbeam analysis - Electron probe microanalyser (EPMA) - Guidelines for performing quality assurance procedures

Introduction: This document was developed to provide a general method for operators of electron probe microanalysers (EPMA) to perform the most complete and reliable instrument diagnostic routine possible in the smallest amount of operator time, instrument time and analysis time. Performing this procedure on their instruments at regularly scheduled intervals will allow the operator to track the quality of an instrument’s elemental qualitative and quantitative performance, and alert the operator of the need for instrument service and calibration shortly after it fails to meet its operating specifications for measurement uncertainty. With equal application of this document to the diagnostics procedure of multiple instruments in a single laboratory, or even multiple instruments managed by different operators in separate laboratories, analysis results can be normalized between instruments using the performance comparison, facilitating analytical reproducibility. The chief product of an analytical laboratory quality assurance (QA) program, ultimately, is confidence – confidence that the analysis of any specimen sent to any laboratory participating in the program will be consistent, correct within tolerance and interchangeable with equivalent analyses of related specimens performed by any other laboratory in the program. In order to maximize confidence, the QA tests and test materials chosen should evaluate the broadest possible range of instrument functionality. In the context of EPMA, this mea

Scope: This document provides guidelines for performing routine diagnostics and quality assurance procedures on electron probe microanalysers (EPMA). It is intended to be used periodically by an instrument’s operator to confirm that the instrument is performing optimally, and to aid in troubleshooting if it is not. It covers the properties of reference materials required and the analysis procedures necessary to independently test and fully evaluate the functionality of the main components of an EPMA system. The analytical procedure described herein is distinct from single-element diagnostic procedures, which can be performed more rapidly. Such procedures are valid for the diffractor position and conditions under which the test is performed, whereas the procedure described herein is intended to qualify an instrument’s capabilities for exploratory analysis of unknowns, trace analysis and non-routine work (such as peak interferences). This document is applicable to EPMA and other wavelength dispersive spectrometer (WDS) systems in which elemental identification and quantification are performed by analysis of the energy and intensity of the characteristic X-ray lines observed in wavelength-dispersed X-ray spectra. It is not directly applicable to elemental analysis using energy dispersive spectrometry (EDS).

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 19463-2018 PDF

ISO 19463-2018 PDF

$113.50 $227.00