ISO 20411-2018 PDF

Surface chemical analysis - Secondary ion mass spectrometry - Correction method for saturated intensity in single ion counting dynamic secondary ion mass spectrometry

$71.50 $143.00 -50%
Product Code: ISO 20411
Stock In Stock
Edition: 1.
Published: 03/2018
Number of Pages: 22
File Size: 1 file, 1 Byte

Available Options

Product Description

Surface chemical analysis - Secondary ion mass spectrometry - Correction method for saturated intensity in single ion counting dynamic secondary ion mass spectrometry

Introduction: For the quantitative analysis of materials using secondary ion mass spectrometry (SIMS), the abundance of a species should be a linear function of its measured signal intensity. However, this relationship can become nonlinear as the count rates rise because of saturation of the detector, which uses a pulse counting system. This causes underestimation of an abundance of high-count-rate species. The nonlinearity of the counting system can be corrected using the relevant method, so that the corrected count rate gives a wider linear range. This document explains how to assess the linearity in the high-count-rate region. The document also provides a correction method for the saturated intensity in a certain situation. It uses a test based on depth profile analysis of two isotopes in a reference material which has a gradual concentration change between low and high concentration regimes. The correction method is based on the approximate intermediate extended dead time model. This document should be used when characterizing a new spectrometer so that it may be operated in an appropriate intensity range or when applying a new analysis condition. It should then be repeated after any substantive modification to the detection circuits, such as the multiplier voltage or the threshold, after replacement of their multiplier, or at approximately 6-monthly intervals. © ISO 2018 – All rights reserved

Scope: This document specifies a method for determining the maximum count rate for an acceptable limit of divergence from linearity of the intensity scale in pulse counting magnetic sector-type secondary ion mass spectrometers or quadrupole secondary ion mass spectrometers. It uses a test based on depth profile analysis of two isotopes in a reference material which has a gradual concentration change between low and high concentration regimes. It also includes a correction method for saturated intensity caused by the dead time of the detector. The correction can increase the intensity range for 95 % linearity so that a higher maximum count rate can be employed for those spectrometers for which the relevant correction equations have been shown to be valid. This document does not apply to time of flight mass spectrometers. This document is only applicable to elements with minor isotopes. It is not applicable if the element is monoisotopic or contains isotopes with equal abundances.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 20411-2018 PDF

ISO 20411-2018 PDF

$71.50 $143.00