IEC 60318-8-2022 PDF

IEC 60318-8-2022 PDF

Electroacoustics-Simulators of human head and ear-Part 8: Acoustic coupler for high-frequency measurements of hearing aids and earphones coupled to the ear by means of ear inserts

$163.93 $327.86 -50%
Product Code: IEC 60318-8
Stock In Stock
Edition: 1.0
Published: 04/2022
Number of Pages: 74
File Size: 1 file, 3 Bytes

Available Options

Product Description

Electroacoustics – Simulators of human head and ear – Part 8: Acoustic coupler for high-frequency measurements of hearing aids and earphones coupled to the ear by means of ear inserts

Introduction: Advancement in hearing aid design makes it possible to increase the bandwidth of hearing aids up to 16 kHz. The 2 cm3 coupler as described in IEC 60318-5 [1]1 is suitable for measurements up to 8 kHz. At frequencies above 8 kHz, high measurement uncertainty will occur in earphone responses, due to acoustic resonances in the coupler. The occluded-ear simulator as described in IEC 60318-4 [2] simulates the human external ear up to 10 kHz and can be used as an acoustic coupler up to 16 kHz. It is designed with a principal cavity length which produces a half-wavelength resonance of the sound pressure at approximately 13,5 kHz. This resonance, which is also present in a person’s ear canal but more controlled by the tympanic membrane, can also cause measurement uncertainty in earphone responses above 10 kHz. Accordingly, there is a need for a well-defined and robust acoustic coupler to be used by designers of transducers (receiver, earphone), and by the designer and dispensers of hearing aids when making measurements on earphones in the frequency range 8 kHz to 16 kHz. The sound pressure developed by an earphone is, in general, not the same in an acoustic coupler as in a person's ear. However, results obtained with an acoustic coupler can be used as a simple and ready means for the exchange of specifications and test data on hearing aids and insert earphones used in audiometry. This document describes an acoustic coupler for loading a hearing aid or insert earphone with a specified

Scope: This part of IEC 60318 describes an acoustic coupler for loading a hearing aid or insert earphone with a specified acoustic impedance when testing its acoustic performance, in the frequency range up to 16 kHz. It is suitable for air-conduction hearing aids and earphones, coupled to the ear by means of ear inserts, earmoulds or similar devices. The acoustic coupler does not simulate the human ear. However, it has an effective volume of only 0,4 cm3, which is small enough not to produce significant resonances in the coupler in the frequency range below 16 kHz. Therefore, it will load the earphone with a known acoustic impedance, which allows repeatable measurements with low uncertainty to be obtained on earphones used in extended high-frequency audiometry.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.