Connectors for electrical and electronic equipment – Tests and measurements – Part 11-1: Climatic tests – Test 11a – Climatic sequence
Introduction: This part of IEC 60512 provides a standard test method for electrical connectors based upon IEC 60068-2-61, which is referenced as a basis. The value of a sequence of climatic tests, particularly for the testing of components, has been witnessed a long time ago by the inclusion of a “climatic sequence” in IEC 60068-1 (in the 2013 edition, it is covered in Clause 6, with guidance in Annex B). With the increasing importance of the IEC Quality Assessment System for Electronic Components (IECQ) it had become necessary to define that test sequence more precisely than could be done therein, with the object of providing for satisfactory reproducibility of the test. IEC 60068-2-61 was then established by IEC TC 104, describing in detail a composite test specifying a “climatic sequence” for specimens of products, primarily components, that is based on Clause 6 of IEC 60068-1:2013, and it includes guidance in informative annexes for specification writers and those performing the test. Test Z/ABDM of IEC 60068-2-61 is a “composite test” as defined in IEC 60068-1 rather than a “sequence” as defined in the same standard. Because of the well-established use of “sequence” in references to Clause 6 of IEC 60068-1:2013, TC 104 decided that “sequence” should have continued to be used in referring to the operations in this composite test. This document also adheres to this decision. This part of IEC 60512 tailors the above mentioned general-purpose composite climatic test to the specific needs
Scope: This part of IEC 60512, when required by the detail (product) specification, is used for testing connectors within the scope of IEC technical committee 48. This test may also be used for similar devices (i.e. when the degradation mechanisms are the same) when specified in a detail (product) specification. The object of this test is to define a standard test method to assess the ability of connectors to function in a specified manner, in a specified environment which might be encountered during normal use, including storage. This document provides a standard composite test method for determining the suitability of connectors when subjected to environmental conditions consisting of a sequence of temperature, humidity and, where required, low air pressure environmental stresses. The order of application of the stresses and the conditions for the change from one step to the next have been chosen to accelerate, amplify and allow potential interactions of degradation mechanisms of the same type as those observed under natural climatic conditions. In this composite test, connector specimens are exposed to environmental tests in a standard order and categorized according to their climatic category as assigned by the detail (product) specification, except that the third group of digits is used as an indication of the number of cycles in step 5 of the damp heat cyclic test according to IEC 60512-11-12. Where any modification is necessary, the relevant connector detail (product) specification provides the necessary information for each step in the method. This test is frequently specified to follow other tests involving mechanical stress, for example tests for robustness of terminations, solderability, shock and vibration, as a means of determining whether the sealing of the specimen has been damaged.
Contents:
- FOREWORD
- INTRODUCTION
- Scope