Fire hazard testing – Part 9-1: Surface spread of flame – General guidance
Introduction: Fires are responsible for creating hazards to life and property as a result of the generation of heat (thermal hazard), and also toxic effluent, corrosive effluent and smoke (non-thermal hazard). Fire hazard increases with the burning area leading in some cases to flashover and a fully developed fire. This is a typical fire scenario in buildings. The surface spread of flame beyond the area of ignition occurs as a result of the creation of a pyrolysis front on the surface of the material, ahead of the flame front, arising from the heating by the flame and external heat sources. The pyrolysis front is the boundary between pyrolysed material and unpyrolysed material on the surface of the material. Combustible vapours are generated within the region of pyrolysed material, which mix with air and ignite, creating the flame front. The surface spread of flame rate is the distance travelled by the flame front divided by the time required to travel that distance. The surface spread of flame rate depends on the heat supplied externally and/or by the flame of the burning material ahead of the burning zone and on the ease of ignition. The ease of ignition is a function of the minimum ignition temperature, thickness, density, specific heat, and thermal conductivity of the material. The heat supplied by the flame depends on the heat release rate, specimen orientation, air flow rate and air flow direction relative to the surface spread of flame direction. In general, materials show one of th
Scope: This part of IEC 60695provides guidance for the assessment of surface spread of flame for electrotechnical products and the materials from which they are formed. It provides: an explanation of the principles of flame spread for both liquids and solids, guidance for the selection of test methods, guidance on the use and interpretation of test results, and informative references This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.
Contents:
- FOREWORD
- INTRODUCTION
- Scope