IEC 60947-9-2-2021 PDF

IEC 60947-9-2-2021 PDF

Low-voltage switchgear and controlgear-Part 9-2: Active arc-fault mitigation systems-Optical-based internal arc-detection and mitigation devices

$239.59 $479.18 -50%
Product Code: IEC 60947-9-2
Stock In Stock
Edition: 1.0
Published: 04/2021
Number of Pages: 180
File Size: 1 file, 6 Bytes

Available Options

Product Description

Low-voltage switchgear and controlgear – Part 9-2: Active arc-fault mitigation systems – Optical-based internal arc-detection and mitigation devices

Introduction: Low-voltage switchgear and controlgear, as well as complementary protective and measuring devices, are installed in assemblies according to IEC 61439 series standards and/or others, which provide rules and requirements for interface characteristics, service conditions, construction, performance and verification. The main objective of these standards is to achieve the safe operation of low-voltage switchgear and controlgear assemblies under normal operating conditions as well as under abnormal operating conditions, e.g. occurrence of overvoltage, overload or short-circuit currents. The case of an arc-fault inside a LV assembly is considered by the following publications: IEC TR 61641, which specify tests requirements for assemblies under internal arc-fault; IEC TR 61439-0:2013, which identifies arc-fault containment in its Annex C; IEC TS 63107, which specifies tests to verify correct integration of internal arc-fault mitigation systems in power switchgear and controlgear assemblies (PSC assemblies) according to IEC 61439-2. Even in a Class I assembly according to IEC TR 61641, the occurrence of an internal arc cannot be completely excluded. Typically, internal arc-faults result from: conducting materials inadvertently left inside equipment during manufacture, installation or maintenance; failures in materials or workmanship; inadvertent contact with a live conductor; entry of small animals such as mice, snakes, ants, etc.; use of an incorrect assembly for the application resu

Scope: This document covers internal arc-fault control devices, hereinafter referred to as IACD, which are intended to: detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by processing (at a minimum) the optical effect of an internal arc-fault, and operate mitigation device (either external or combined) in order to minimize the effects of the internal arc-fault (see Figure 1). For the purpose of this document the terms "light" or "optical" covers more than visible spectra. They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see Annex D). For combined-type IACD, this document is considered in addition to the relevant product standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance to the relevant product standard is mandatory and cannot be claimed by testing to this document alone. NOTE 1 Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series. NOTE This figure displays a simplified IACD schematic with only one optical sensor and no other sensing means that can be used for secondary confirmation of an arcing fault, such as current sensing. Key assembly enclosure internal arc-fault optical sensor processing unit trigger output used to operate e.g. mitigation device Figure 1 – Optical-based IACD schematic (stand-alone type and no secondary sensor) Therefore, this document covers the following: internal arc-fault control device (stand-alone, multifunction or combined); one or more associated sensor(s) used to detect optical effect of the internal arc-fault; sensor(s), sensing another physical effect, to confirm the fault; associated or combined mitigation device. – 12 – IEC 60947-9-2:2021 © IEC 2021 An IACD is not intended to trigger under normal operation of low-voltage switchgear and controlgear (i.e. absence of internal arc-fault), including normal arcing associated with operation of disconnecting and switching devices. This document only covers the following methods: optical detection of the light caused by an internal arc-fault; optional confirmation of internal arc-fault by line current measurement. Many different conductive materials

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60947-9-2-2021 PDF

IEC 60947-9-2-2021 PDF

$239.59 $479.18