IEC 61008-1-2024 PDF

IEC 61008-1-2024 PDF

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)-Part 1: General rules

$255.36 $510.71 -50%
Product Code: IEC 61008-1
Stock In Stock
Edition: 4.0
Published: 11/2024
Number of Pages: 244
File Size: 1 file, 7 Bytes

Available Options

Product Description

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) – Part 1: General rules

Introduction: The purpose of this document is to harmonize as far as practicable all rules and requirements of a general nature applicable to RCCBs in order to obtain uniformity of requirements and tests and to avoid the need for testing to different standards. All those parts which can be considered as general have therefore been gathered in this document, e.g. temperature-rise, dielectric properties, etc. For each type of RCCB, only two main documents are used to determine all requirements and tests: 1) this document; 2) the relevant product standard covering RCCBs: IEC 61008-2-1, Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) – Part 2-1: RCCBs according to classification 4.1.1; or IEC 61008-2-2, Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) – Part 2-2: RCCBs according to classification 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6 For Type F and Type B RCCBs, IEC 62423 applies in addition to the IEC 61008 series.

Scope: This document gives general requirements and tests for residual current operated circuit- breakers without integral overcurrent protection for household and similar uses (hereafter referred to as RCCBs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. RCCBs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCCBs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCCBs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. NOTE 1 The requirements for RCCBs are in line with the group safety publication IEC 60755. NOTE 2 RCCBs of type AC and type A are covered by the IEC 61008 series. RCCBs of type F and type B are covered by IEC 62423 in conjunction with the IEC 61008 series. NOTE 3 Installation and selection rules for RCCBs are given in the IEC 60364 series. NOTE 4 Installation and application rules of RCCBs in ZA is given in SANS 10142-1. RCCBs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCCBs used in locations which have severe environmental conditions. RCCBs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3). NOTE 5 For environments with higher pollution degrees, enclosures giving the appropriate degree of protection can be used. NOTE 6 For RCCBs having a deg

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope