IEC 61009-1-2024 PDF

IEC 61009-1-2024 PDF

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

$271.12 $542.23 -50%
Product Code: IEC 61009-1
Stock In Stock
Edition: 4.0
Published: 11/2024
Number of Pages: 272
File Size: 1 file, 5.4 MB

Available Options

Product Description

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

Introduction: The purpose of this document is to harmonize as far as practicable all rules and requirements of a general nature applicable to RCBOs in order to obtain uniformity of requirements and tests and to avoid the need for testing to different standards. All those parts which can be considered as general have therefore been gathered in this document, e.g., temperature-rise, dielectric properties, etc. For each type of RCBO, two main documents are used to determine all requirements and tests: 1) this document; 2) the relevant product standard covering RCBOs: IEC 61009-2-1, Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) – Part 2-1: RCBOs according to classification 4.1.1; IEC 61009-2-2, Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) – Part 2-2: RCBOs according to classification 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6. For Type F and Type B RCBOs, IEC 62423 applies in addition to the IEC 61009 series.

Scope: This document gives general requirements and tests for residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A. RCBOs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. These devices are also intended to protect against overcurrents in the wiring installations of buildings and similar applications. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCBOs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCBOs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. These devices also perform the function of making, carrying and breaking overcurrents under specified conditions. NOTE 1 The requirements for RCBOs are in line with the group safety publication IEC 60755. NOTE 2 RCBOs of type AC and type A are covered by the IEC 61009 series. RCBOs of type F and type B are covered by IEC 62423 in conjunction with the IEC 61009 series. NOTE 3 Installation and selection rules for RCBOs are given in the IEC 60364 series. NOTE 4 The content of this document related to operation under residual current conditions is based on IEC 61008-1. The content of this document related to protection against overcurrents is based on IEC 60898-1. RCBOs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Addition

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61009-1-2024 PDF

IEC 61009-1-2024 PDF

$271.12 $542.23