Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-091: Particular requirements for cabinet X-ray systems
Introduction: IEC 61010-1 specifies the safety requirements that are generally applicable to all equipment within its scope. For certain types of equipment, the requirements of IEC 61010-1 and its amendments will be supplemented or modified by the special requirements of one, or more than one, particular Part 2s of the standard, which are to be read in conjunction with the Part 1 requirements. This document has been prepared, based on IEC 61010-1:2010 including its Amendment 1:2016, to specify additional safety requirements for cabinet X-ray systems. It provides additional guidance for construction and assessment of extra high voltage circuits, mechanical HAZARDS and ionizing radiation HAZARDS which can be present in this type of equipment. This document has been written to provide protection against both radiation HAZARDS from the direct X-ray beam and any scattered X-radiation caused by reflections of the X-ray beam on any part of the equipment or on the sample subjected to X-rays. The minimum safety requirements specified in this document are considered to provide for a practical degree of safety in the operation of cabinet X-ray systems.
Scope: 1.1.1 Equipment included in scope Deletion: Delete the first paragraph. Replacement: Replace the second paragraph (above items a) to c)) with the following new text: This part of IEC 61010 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below. Addition: Add the two following new paragraphs at the end of the subclause: Equipment covered by this document can be both PROTECTED EQUIPMENT or PARTIALLY PROTECTED EQUIPMENT, with X-ray generator voltage up to 500 kV. A cabinet X-ray system is a system that contains an X-ray tube installed in a cabinet, which, independently of existing architectural structures except the floor on which it may be placed, is intended to contain at least that portion of a material being irradiated, provide radiation attenuation and prevent operator access to the radiation beam, during generation of X-radiation. These cabinet X-ray systems are used in industrial, commercial, and public environments, for example, to inspect materials, to analyse materials, and to screen baggage. 1.1.2 Equipment excluded from scope Addition: Add the following new items to the list: aa) Equipment intended to apply X-radiation to humans or animals; bb) Equipment incorporating an X-ray tube but not incorporating complete shielding against X-radiation HAZARDS, such as: – equipment intended to be used within a shielded room which excludes personnel during operation; – equipment intended to be used with separate portable or temporary shielding; – equipment intended to produce an emerging beam of X-radiation. – 8 – IEC 61010-2-091:2019 IEC 2019 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following new text to the end of the first paragraph: This part of IEC 61010 specifies requirements for the design and methods of construction of cabinet X-ray systems to provide adequate protection for OPERATORS, bystanders, trained service personnel and the surrounding area against unintentionally-emitted X-radiation and from mechanical HAZARDS related to their conveyors.
Contents: