Controlgear for electric light sources – Safety – Part 2-3: Particular requirements – AC or DC supplied electronic controlgear for fluorescent lamps
Introduction: This second edition of IEC 61347-2-3, published in conjunction with IEC 61347-1, represents an review of the first edition of IEC 61347-2-3. The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include additional requirements, as necessary. All parts which make up IEC 61347-2 are intended to be self-contained and, therefore, do not include references to each other. However, for the case of emergency lighting lamp control gear, some cross-referencing has been necessary. Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted as meaning that all requirements of the clause in question of part 1 apply, except any which are clearly inapplicable to the specific type of lamp control gear covered by this particular part of IEC 61347-2. The technical requirements in this document compared to IEC 61347-2-3:2011 and IEC 61347-2-3:2011/AMD1:2016 are essentially unchanged. Nevertheless, a new edition of this document could not be avoided, as without the introduction of dated references to IEC 61347-1:2015 and I
Scope: This part of IEC 61347 specifies safety requirements for electronic controlgear for use on AC supplies at 50 Hz or 60 Hz up to 1 000 V and/or on DC supplies up to 1 000 V with lamp operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, low-pressure UV lamps, and other fluorescent lamps for high-frequency operation. NOTE 1 Requirements for centrally supplied controlgear for emergency lighting are given in Annex B. This also includes performance requirements as far as they are considered to be safety-related with respect to reliable emergency operation. NOTE 2 Requirements for emergency lighting controlgear operating from non-centralised power supplies are given in IEC 61347-2-7. NOTE 3 Performance requirements are the subject of IEC 60929. Performance requirements are the subject of IEC 60929. Particular requirements for electronic control gear with means protection against overheating are given in Annex C. For emergency lighting operation, particular requirements for control gear operated from a central supply are given in Annex J. Performance requirements appropriate to the safe operation of emergency lighting are also contained in Annex J. Requirements for emergency lighting control gear operating from non-centralised power supplies are given in IEC 61347-2-7. NOTE Performance requirements detailed by Annex J are those considered to be safety-related with respect to reliable emergency operation.
Contents:
- FOREWORD
- INTRODUCTION
- Scope