IEC 61400-6-2025 PDF

IEC 61400-6-2025 PDF

Wind energy generation systems-Part 6: Tower and foundation design requirements

$775.52 $1,551.03 -50%
Product Code: IEC 61400-6
Stock In Stock
Edition: 1.1
Published: 06/2025
Number of Pages: 314
File Size: 1 file, 4 Bytes

Available Options

Product Description

Wind energy generation systems – Part 6: Tower and foundation design requirements

Introduction: This document has been developed for the design of onshore wind turbine towers and foundations that will build on and complement the IEC 61400-1 relating to design criteria and provide a complete set of technical requirements for the structural and geotechnical design. The requirements are also applicable to wind turbines covered by IEC 61400-2. It is envisaged that the proposed work will be followed by the development of another part, directed towards the design of offshore support structures, thus also complementing IEC 61400-3-1. Civil engineering practices associated with the scope of the standard have regional variations. It is not the intention of this document to conflict with those practices but to supplement them particularly in ensuring that all important features of typical wind turbine towers and foundations are fully and correctly considered. To this end, the relevant parts in existing standards for design of steel and concrete structures and for geotechnical design have been identified for participating countries and regions. The principles included in this document apply to the sections of the tower of an offshore fixed structure above the splash zone if the loading has been calculated according to IEC 61400-3-1. This document will include the evaluation and calibration of partial safety factors for material strengths to be used together with the safety elements in IEC 61400-1 and IEC 61400-2 for loads and for verification of static equilibrium. INTRODUCTION to

Scope: This part of IEC 61400 specifies requirements and general principles to be used in assessing the structural integrity of onshore wind turbine support structures (including foundations). The scope includes the geotechnical assessment of the soil for generic or site specific purposes. The strength of any flange and connection system connected to the rotor nacelle assembly (including connection to the yaw bearing) are designed and documented according to this document or according to IEC 61400-1. The scope includes all life cycle issues that may affect the structural integrity such as assembly and maintenance. The assessment assumes that load data has been derived as defined in IEC 61400-1 or IEC 61400-2 and using the implicit reliability level and partial safety factors for loads.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61400-6-2025 PDF

IEC 61400-6-2025 PDF

$775.52 $1,551.03