Safety of transformers, reactors, power supply units and combinations thereof – Part 2-7: Particular requirements and tests for transformers and power supply units for toys
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is used because of responsibility for safety extra-low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2005, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is used for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example, an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement: This part of IEC 61558 deals with the safety of transformers for toys and power supply units incorporating transformers for toys. Transformers for toys incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers transformers for toys and power supply units incorporating transformers for toys. This document is applicable to stationary and portable single-phase, air-cooled (natural or forced) dry-type transformers. The windings can be encapsulated or non-encapsulated. This document is applicable to independent transformers and transformers for specific use. For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe takes precedence. The rated supply voltage does not exceed 250 V AC. The rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated output does not exceed 200 VA and a rated output current does not exceed 10 A. The no-load output voltage does not exceed 33 V AC or 46 V ripple-free DC, and the rated output voltage does not exceed 24 V AC or 33 V ripple-free DC. In general, this document does not take into consideration children playing with the transformers. This document is not applicable to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformers. Attention is drawn to the following if necessary: for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.); measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing; the different conditions for transportation, storage, and operation of the transformers; additional requirements in accordance with other appropriate standards and national rules can be applicable to transformers intended
Contents:
- FOREWORD
- INTRODUCTION
- Scope