Instrument transformers – Part 10: Additional requirements for low-power passive current transformers
Introduction: Low-power passive current transformers (LPCT) are based on passive technologies without any active electronic components. They can have an output signal proportional to the primary current, for example iron core coils with integrated shunt as a current to voltage converter (primary converter) or they can have an output signal proportional to the derivative of the primary current, for example air-core coils (Rogowski coils). This part of IEC 61869 does not cover the air-core coils with active integrator. According to a general block diagram given in Figure 601 of IEC 61869-6:2016, the low-power passive current transformers do not use an active primary converter (i.e. without any active electronic component); therefore, there is no need for primary power supply. Additionally, neither the secondary converter nor the secondary power supply is used. The general block diagram of a low-power passive current transformer is given in Figure 1001. The applied technology decides which part is necessary for the realization of a low-power passive current transformer, i.e. it is not absolutely necessary that the transmitting cable or primary converter described in Figure 1001 be included in the low-power passive current transformer. The derivative LPCT solution considers only the air-core coil as the primary sensor and the transmission cable as the transmitting system. In this technology, the primary converter is not considered. In case of a proportional LPCT solution, the ferromagnetic-cor
Scope: This part of IEC 61869 is a product standard and covers only additional requirements for low- power passive current transformers. The product standard for low-power passive current transformers comprises IEC 61869-1, together with IEC 61869-6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive current transformers with analogue output for use with electrical measuring instruments or electrical protective devices having a rated frequency from 15 Hz to 100 Hz. This document covers low-power passive current transformers used for measurement or protection and multi-purpose low-power passive current transformers used for both measurement and protection. Subclause 5.6.1001 covers the accuracy requirements that are necessary for low-power passive current transformers for use with electrical measuring instruments. Subclause 5.6.1002 covers the accuracy requirements that are necessary for low-power passive current transformers for use with electrical protective relays, and particularly for forms of protection in which the prime requirement is to maintain the accuracy up to several times the rated current. If required, the transient accuracy of low-power passive current transformers during fault is also given in 5.6.1002. Low-power passive current transformers have analogue voltage output only (for digital output or for technology using any kind of active electronic components refer to IEC 61869-82). Such low-power passive current transformers can include the secondary signal cable (transmitting cable). The principle of operation of derivative low-power passive current transformers using air-core coils (Rogowski coils) is given in Annex 10B and the principle of operation of proportional low-power passive current transformers using iron-core coils with integrated shunt is given in Annex 10C.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 5.1001 Standard values for rated primary current (Ipr)
- 5.1002 standard values for rated extended primary current factor (Kpcr)
- 5.1003 Standard value of rated continuous thermal current (Icth)
- 5.1004 Standard values of rated secondary voltage (Usr)
- 5.1005 Short-time current ratings
- 5.1006 Rated phase offset (φor)
- 6.601 Requirements for optical transmitting system and optical output link
- 6.602 Requirements for electrical transmitting system and electrical wires for
- 6.603 Signal-to-noise ratio
- 6.604 Failure detection and maintenance announcement
- 6.605 Operability
- 6.606 Reliability and dependability
- 6.607 Vibrations
- 601 Information to be given with enquiries, tenders and orders
- 601.1 Designation
- 601.2 Dependability