Power installations exceeding 1 kV AC and 1,5 kV DC – Part 1: AC (Commented Version)
Introduction: This part of IEC 61936 contains the minimum requirements f or the design, erection, and verif ication of high voltage power installations greater than 1 kV AC. The rules are intended to provide f or the safety of persons, livestock and property against dangers and damage which may arise in the reasonable use of such electrical installations and to provide for the proper f unctioning of those installations. There are many provincial, national and regional laws, standards and internal rules dealing with the matter coming within the scope of this document regarding high voltage power installations. These practices have been taken as a basis for this work. This part of IEC 61936 contains the minimum requirements valid f or IEC countries and some additional inf ormation which ensures an acceptable reliability of an installation and its safe operation. The publication of this standard is believed to be a decisive step towards the gradual alignment all over the world of the practices concerning the design and erection of high voltage power installations. This third edition of IEC 61936-1, first published in 2001, follows worldwide feedback to improve clarity. It continues the effort to towards the alignment all over the world of practices concerning the design and erection of high voltage power installations. Particular requirements f or transmission and distribution installations, as well as particular requirements f or power generation and industrial installations, are included in
Scope: This part of IEC 61936 provides common rules requirements f or the design and the erection of electrical power installations in systems with nominal voltages above exceeding 1 kV AC and nominal f requency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended. For the purpose of interpreting this document, an electrical power installation is considered to be one of the f ollowing: a) substation, including substation f or railway power supply; b) electrical power installations on mast, pole and tower, switchgear and/or transformers located outside a closed electrical operating area; c) one (or more) power station(s) located on a single site, the electrical power installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded; d) the electrical system of a factory, industrial plant or other industrial, agricultural, commercial or public premises; e) electrical power installations erected on offshore platforms f acilities f or the purpose of generation, transmission, distribution and/or storage of electricity e.g. offshore wind power f arms; 1 f ) transition towers/poles (between overhead lines and underground lines). 2 The electrical power installation includes, among others, the f ollowing equipment: rotating electrical machines; switchgear; transf ormers and reactors; converters; cables; wiring systems; batteries; capacitors; earthing systems; buildings and f ences which are part of a closed electrical operating area; associated protection, control and auxiliary systems; large air core reactor. NOTE 1 In g eneral, a standard for an item o f equipment standards take precedence over the requirements of this d o cument. This document does not apply to the design and erection of any of the f ollowing: overhead and underground lines between separate electrical power installations; IEC 61936-1:2021 CMV © IEC 2021 – 13 – electric electrified railway tracks and rolling stock; 3 mining equipment and installations; f luorescent lamp installations; installations on ships according to IEC 60092 (all pa
Contents:
- FOREWORD
- INTRODUCTION
- Scope