Railway applications – Electromagnetic compatibility – Part 5: Emission and immunity of fixed power supply installations and apparatus
Introduction: The requirements of this part of IEC 62236 have been specified so as to ensure a level of electromagnetic emission which will cause minimal disturbance to other equipment. The levels, however, do not cover the following cases: a) where the probability of an occurrence likely to produce emissions in excess of those which would normally be experienced is extremely low, a) which may occur with an extremely low probability of occurrence in any location; b) where highly susceptible apparatus will be is used in close proximity of the equipment covered by this document, in which case further measures may have to be taken. The emission limits given are on the basis that the equipment of the product family range is installed in railway traction substation areas.
Scope: This part of IEC 62236 applies to emission and immunity aspects of EMC for fixed power supply installations and electrical and electronic apparatus and systems intended to be used in these installations for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this document since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment. The limits in this standard do not apply to intentional communication signals. If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirements in this document are not intended to be applicable to the intentional transmission from a radio- transmitter as defined by the ITU. The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated: a) within the boundary of a substation which delivers electric power to a railway; b) beside the track for the purpose of controlling or regulating the railway power supply, including power factor correction and filtering; c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage; NOTE 1 Examples are one conductor of a 25-0-25 kV 50 Hz system and the 110 kV 16,7 Hz supply systems. N
Contents:
- FOREWORD
- INTRODUCTION
- Scope