IEC 62282-3-200 (REDLINE + STANDARD)-2025 PDF

IEC 62282-3-200 (REDLINE + STANDARD)-2025 PDF

Fuel cell technologies - Part 3-200: Stationary fuel cell power systems - Performance test methods

$407.31 $814.61 -50%
Product Code: IEC 62282-3-200 (REDLINE + STANDARD)
Stock In Stock
Edition: 3.0
Published: 09/2025
Number of Pages: 246
File Size: 1 file, 4.7 MB

Available Options

Product Description

Fuel cell technologies - Part 3-200: Stationary fuel cell power systems - Performance test methods

Introduction: This part of IEC 62282 describes how to measure the performance of stationary fuel cell power systems for residential, commercial, agricultural and industrial applications. This document describes type tests and their test methods only. In this document, no routine tests are required or identified, and no performance targets are set. The following fuel cell types have been considered: alkaline fuel cells (AFC); phosphoric acid fuel cells (PAFC); polymer electrolyte fuel cells (PEFC); molten carbonate fuel cells (MCFC); solid oxide fuel cells (SOFC). A related but independent standard IEC 62282-3-201 on the performance test methods of small stationary fuel cell power systems has been aligned with this document.

Scope: This part of IEC 62282 covers operational and environmental aspects of the stationary fuel cell power systems performance. The test methods apply as follows: power output under specified operating and transient conditions; electrical and heat recovery efficiency under specified operating conditions; environmental characteristics, for example, exhaust gas emissions, noise, under specified operating and transient conditions. This document applies to all kinds of stationary fuel cell technologies, such as: alkaline fuel cells (AFC); phosphoric acid fuel cells (PAFC); polymer electrolyte fuel cells (PEFC); molten carbonate fuel cells (MCFC); solid oxide fuel cells (SOFC). This document does not provide coverage for electromagnetic compatibility (EMC). This document does not apply to small stationary fuel cell power systems with rated electric power output of less than 10 kW which are dealt with in IEC 62282-3-201. Fuel cell power systems may can have different subsystems depending upon types of fuel cell and applications, and they have different streams of material and energy into and out of them. However, a common system diagram and boundary has been defined for evaluation of the fuel cell power system (see Figure 1). The following conditions are considered in order to determine the system boundary of the fuel cell power system: all energy recovery systems are included within the system boundary; all kinds of electric energy storage devices are considered outside the system boundary; calculation of the heating value of the input fuel (such as natural gas, propane gas and pure hydrogen gas) is based on the conditions of the fuel at the boundary of the fuel cell power system. The document does not provide safety requirements for the testing of stationary fuel cell power systems. Details on safe operation of the tested system can be obtained from the manufacturers instructions. IEC 62282-3-200:2025 RLV © IEC 2025 Key Fuel cell power system including subsystems. The interface is defined as a conceptual or functional one instead of hardware such as a power package. Subsystems: fuel cell module, fuel processor, etc. These subsystem configurations depend on the kind of fu

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 10 Test methods and computation of test results

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62282-3-200 (REDLINE + STANDARD)-2025 PDF

IEC 62282-3-200 (REDLINE + STANDARD)-2025 PDF

$407.31 $814.61