Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems
Introduction: This part of IEC 62282 provides consistent and repeatable test methods for the electrical, thermal and environmental performance of small stationary fuel cell power systems. This document limits its scope to small stationary fuel cell power systems (electrical power output below 10 kW, which is typical for residential, small commercial and off-grid applications) and provides test methods specifically designed for them in detail. It is based on the latest edition of IEC 62282-3-200, which generally describes performance test methods that are common to all types of fuel cells. This document is intended for manufacturers of small stationary fuel cell power systems and/or those who evaluate the performance of their systems for certification purposes, or both. Users of this document may can selectively execute test items that are suitable for their purposes from those described in this document. This document is not intended to exclude any other methods. INTRODUCTION to Amendment 1 This amendment to IEC 62282-3-201:2017 provides a method of estimating the electric and heat recovery efficiency of small stationary fuel cell power systems for a duration of up to ten years of operation. Furthermore, this amendment to IEC 62282-3-201:2017 provides an evaluation method for electric demand-following small stationary fuel cell power systems, which are operating at changing levels of power output. It has been developed as a reference for the life cycle assessment calculations in IEC TS 622
Scope: This part of IEC 62282 provides test methods for the electrical, thermal, and environmental performance of small stationary fuel cell power systems that meet the following criteria: output: rated electric power output of less than 10 kW; output mode: grid-connected/independent operation or stand-alone operation with single- phase AC output or 3-phase AC output not exceeding 1 000 V, or DC output not exceeding 1 500 V; NOTE The limit of 1 000 V for alternating current comes from the definition for "low voltage" given in IEC 60050-601:1985, 601-01-26. operating pressure: maximum allowable working pressure of less than 0,1 MPa (gauge) for the fuel and oxidant passages; fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen, etc.) or liquid fuel (kerosene, methanol, etc.); oxidant: air. This document describes type tests and their test methods only. No routine tests are required or identified, and no performance targets are set in this document. This document provides test methods to be carried out under laboratory conditions. This document covers fuel cell power systems whose primary purpose is the production of electric power and whose secondary purpose may can be the utilization of heat. Accordingly, fuel cell power systems for which the use of heat is primary, and the use of electric power is secondary are outside the scope of this document. All systems with integrated batteries are covered by this document. This includes systems where batteries are recharged internally or recharged from an external source. This document does not cover additional auxiliary heat generators that produce thermal energy.
Contents:
- FOREWORD
- INTRODUCTION
- Scope