IEC 62568-2015 PDF

IEC 62568-2015 PDF

Overhead lines-Method for fatigue testing of conductors

$72.51 $145.02 -50%
Product Code: IEC 62568
Stock In Stock
Edition: 1.0
Published: 07/2015
Number of Pages: 38
File Size: 1 file, 415 Bytes

Available Options

Product Description

Overhead lines – Method for fatigue testing of conductors

Introduction: Fatigue behaviour of conductors cannot simply be calculated from the fatigue characteristics of the materials used and the stresses that occur. Fatigue characteristics of conductors must be determined by fatigue tests conducted on specific conductor/clamp systems reproducing as closely as possible the field loading conditions. In such tests, the fatigue life must be determined as a function of some measure of vibration intensity rather than of the stress or stress combination that causes the failure. Fatigue test data are available for only a small fraction of the conductor sizes and types that are in use, and such data are expensive to acquire. Since none of the above parameters is simply related to the fatigue-initiating stresses, results from tests on one conductor size are not necessarily applicable to others. This IEC Standard is based on these considerations and others explained in Annex A. The user of this standard is encouraged to consult this annex in order to understand the origin of some of the requirements herein.

Scope: This International Standard provides test procedures to measure the fatigue characteristics of conductor/clamp systems. For the purposes of this standard, clamps shall be of the metallic type only. Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 antinode amplitude mid-loop single peak vibration amplitude 2.2 bending amplitude peak-to-peak vibration amplitude of conductor with respect to the clamp, measured 89 mm from the last point of contact between the conductor and the clamp 2.3 failure criterion benchmark at which the test is deemed terminated. Note 1 to entry: Two different failure criteria may be chosen: a) failure of the first wire, or b) failure of three wires or of 10% of the total number of envelope wires for composite conductors, or of the total number of wires for homogeneous conductors 2.4 idealized bending stress alternating stress amplitude calculated based on the measured bending amplitude 2.5 idealized dynamic stress alternating stress amplitude calculated based on the measured fymax product 2.6 idealized strain computed dynamic bending alternating strain obtained by dividing the idealised stress by the Young’s modulus of the outer layer material Note 1 to entry: This calculated idealized strain does not correspond to the strain measured on given wires at the exit of the clamp 2.7 resonance fatigue test cyclic motion imposed on a conductor in a vertical plane at a resonant frequency of the system – 18 – IEC 62568:2015 © IEC 2015 AVANT-PROPOS .................................................................................................................. 19 INTRODUCTION ................................................................................................................... 21 Domaine d’application ................................................................................................... 22 Termes et définitions ..................................................................................................... 22 Symboles et abréviations ............................................................................................... 23 Exigences .........................

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62568-2015 PDF

IEC 62568-2015 PDF

$72.51 $145.02