Electroacoustics – Methods to determine corrections to obtain the free-field response of a sound level meter
Introduction: The performance specification International Standard for sound level meters, IEC 61672-1, requires that at least one model of sound calibrator, conforming to the requirements of IEC 60942 be specified in the instruction manual for checking and maintaining the correct indication on the display of the sound level meter at the calibration check frequency. The sound level meter manufacturer specifies the adjustment value to be applied to obtain the required indication on the display in response to the sound pressure level generated by the sound calibrator, in order to optimize performance over the complete frequency range. In addition, various corrections need to be available over a range of frequencies in order for a periodic test of a sound level meter to be performed according to IEC 61672-3. For example, corrections are needed for any effects of the sound level meter case or of accessories such as windscreens on the equivalent free-field sound level. Information on these corrections is also required by users of sound level meters and sound calibrators on a regular basis. Also, a manufacturer producing a sound level meter to the specifications of IEC 61672-1, may recommend, in the instruction manual, the use of a sound calibrator, comparison coupler or electrostatic actuator to determine the acoustical response of a sound level meter at various frequencies. In this case the manufacturer is required to provide corrections to obtain equivalent sound levels that would be displaye
Scope: This International Standard provides information on the corrections required over a range of frequencies in order for a periodic test of a sound level meter to be performed according to IEC 61672-3. These corrections include: corrections for the typical effects of reflections from the case of the sound level meter and diffraction of sound around the microphone; corrections for the deviation of the typical microphone frequency response from a uniform frequency response, where the actual microphone response cannot be measured; corrections for the influence on the frequency response of a typical microphone of a specified windscreen and any other accessory that is part of the configuration for normal use of the particular sound level meter submitted for testing. This International Standard includes discussion about uncertainties of measurement of the required corrections. In some instances a maximum permitted expanded uncertainty for the manufacturer or testing laboratory is given. This maximum permitted expanded uncertainty excludes any component due to the variability of different samples of artefact (for example, microphone or windscreen). It should be noted that if large uncertainties of measurement are quoted for each of the individual corrections, when they are combined to account for the configuration of sound level meter under test, the large individual uncertainties may result in a failure to conform to the maximum permitted expanded uncertainties of measurement given in Table A.1 of IEC 61672-1:—1 and hence a failure of the sound level meter to conform to IEC 61672-1 In addition, this International Standard describes methods for determining these corrections, over the frequency range of interest, and explains the adjustment value at the calibration check frequency to be quoted by the manufacturer of the sound level meter (also required by IEC 61672-3). When the sound level meter manufacturer recommends the use of a sound calibrator, comparison coupler, or an electrostatic actuator for periodic testing of the acoustical response of a sound level meter at various frequencies, this International Standard describes methods of measurement of the corrections req
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 10 Determination of corrections for the deviation of the microphone free-field
- 11 Determination of corrections for the use of windscreens and similar accessories
- 12 Determination of corrections over a range of frequencies when a sound calibrator
- 13 Determination of corrections over a range of frequencies when a comparison
- 14 Determination of corrections over a range of frequencies when an electrostatic
- 15 Documentation