Radiation protection instrumentation – Spectroscopy-based alarming personal radiation detectors (SPRD) for the detection of illicit trafficking of radioactive material
Introduction: It is important to detect illicit and inadvertent movement of radioactive materials in the form of radiation sources and contaminated metallurgical scrap. Radioactive sources out of regulatory control, so-called “orphan sources”, have frequently caused serious radiation exposures and widespread contamination. Although illicit trafficking of nuclear and other radioactive materials is not a new problem, concern about a nuclear “black market” has increased particularly in view of its terrorist potential. In response to the technical policy of the International Atomic Energy Agency (IAEA), the World Customs Organization (WCO), and the International Criminal Police Organization (Interpol) related to the detection and identification of special nuclear materials and security trends, nuclear instrumentation companies have developed and manufactured radiation instrumentation to assist in the detection of illicit movement of radioactive and special nuclear materials. This type of instrumentation is widely used for security purposes at nuclear facilities, border control checkpoints, and international seaports and airports. To ensure that measurement results made at different locations are consistent, it is imperative that radiation instrumentation be designed to specifications based upon agreed performance requirements. IEC standards have been developed to establish performance requirements for personal radiation detectors, radiation portal monitors, highly sensitive gamma and neutron d
Scope: This document applies to Spectroscopy-based alarming Personal Radiation Detectors (SPRD). SPRDs detect and identify gamma radiation and may detect neutron radiation. SPRDs can be worn on a belt or in a pocket to alert the wearer of the presence of a radiation source. SPRDs provide search, similar to that of a Personal Radiation Device (PRD), and identification capability to identify radiation sources. They can discriminate between alarms caused by Naturally Occurring Radioactive Materials (NORM) or medical radionuclides and alarms from industrial sources or Special Nuclear Material (SNM). This document establishes performance requirements and specifies general characteristics, general test conditions, radiological, climatic, mechanical, and electromagnetic characteristics. This document also provides test methods that are used to determine if an SPRD meets the stated requirements. This document does not apply to the performance of radiation protection instrumentation which is covered in IEC 61526 and IEC 60846-1. SPRDs are not intended for accurate measurement of personal (Hp(10)) or ambient (H*(10)) dose equivalent (rate).
Contents:
- FOREWORD
- INTRODUCTION
- Scope