Methods for calculating size specific dose estimates (SSDE) for computed tomography
Introduction: The SIZE SPECIFIC DOSE ESTIMATE (SSDE) is an estimate of the average ABSORBED DOSE to the scan volume that takes into account the ATTENUATION of the anatomy being scanned (using the WATER EQUIVALENT DIAMETER DW) and the RADIATION OUTPUT of the CT SCANNER (using CTDIVOL). SSDE is intended to provide a dose estimate for PATIENTs of all sizes. SSDE, which is given in units of mGy, is especially important for small paediatric PATIENTS since the corresponding applied level of RADIATION (CTDIVOL, also given in units of mGy) does not adequately indicate the absorbed RADIATION DOSE. SSDE is calculated using a SSDE CONVERSION FACTOR AT LONGITUDINAL POSITION Z (ƒ) and the CTDIVOL AT LONGITUDINAL POSITION Z, CTDIVOL(z), where ƒ is a function of the WATER EQUIVALENT DIAMETER AT LONGITUDINAL POSITION Z, DW(z), and the size of the CTDI PHANTOM used to report CTDIVOL. ƒ is given in normative Annex A. This document provides a methodology (in Clause 4) for a MANUFACTURER to validate their method for calculating DW(z), which is used for the determination of 𝑓𝑓 and the calculation of SSDE. This method calculates a reference WATER EQUIVALENT DIAMETER AT LONGITUDINAL POSITION Z, DW,REF(z), and compares it against a known PHANTOM dimension and the implemented values of WATER EQUIVALENT DIAMETER AT LONGITUDINAL POSITION Z, DW,IMP(z). PHANTOM types and tolerances are also specified. NOTE 1 The definition of SSDE used in this document differs from that of AAPM Report No. 204 [1]1 in that AAPM Report
Scope: This document applies to CT SCANNERS that are able to display and report CTDIVOL in accordance with IEC 60601-2-44, and RADIATION dose index monitoring software (RDIMS) for the purpose of calculating, displaying and recording the SIZE SPECIFIC DOSE ESTIMATE (SSDE) and its associated components. Specifically, this document provides standardized methods and requirements for calculating, displaying, or recording of SSDE, SSDE(z), WATER EQUIVALENT DIAMETER (DW), and DW(z), where z represents a specific longitudinal position of the scanned object. This document provides a method of determining a reference WATER EQUIVALENT DIAMETER, DW,REF(z), using CT scans of two cylindrical water PHANTOMS and one or more anthropomorphic PHANTOM(S), which conform to the specifications defined in this document. The method of calculating the WATER EQUIVALENT DIAMETER that is implemented by the MANUFACTURER, DW,IMP(z), is tested and validated against DW,REF(z) using the TEST OBJECTS and methods defined within this document. This document also describes the methods for calculating SSDE and DW, which represent the average values of SSDE(z) and DW(z) over the RECONSTRUCTION LENGTH. NOTE This standardization is important to ensure that comparisons between reported SSDEs are valid.
Contents:
- FOREWORD
- INTRODUCTION
- Scope