IEC/IEEE 63113-2021 PDF

IEC/IEEE 63113-2021 PDF

Nuclear facilities-Instrumentation important to safety-Spent fuel pool instrumentation

$132.41 $264.81 -50%
Product Code: IEC/IEEE 63113
Stock In Stock
Edition: 1.0
Published: 04/2021
Number of Pages: 60
File Size: 1 file, 20 Bytes

Available Options

Product Description

Nuclear facilities – Instrumentation important to safety – Spent fuel pool instrumentation

Introduction: a) Technical background, main issues and organization of the Standard This IEC/IEEE standard sets out the requirements for instrumentation to monitor spent fuel pool water level and temperature in nuclear facilities as well as radiation monitoring in the vicinity of the pool. Prior to the accident at Fukushima Daiichi, spent fuel pool monitoring in nuclear power plants was provided mainly to enable operators to monitor pool temperature at a location near the top of the pool. It was also used to determine that the water level remained below the point where flooding of operational areas would be a concern and above the level assumed in safety analyses that evaluated the release of fission products from the pool in the event of a fuel handling accident. In general, robust spent fuel pools protect the fuel from physical damage and use highly reliable coolant systems that ensure continuous decay heat removal. Monitoring of the pool cooling system and drain taps at the bottom of the pool were considered sufficient to confirm pool cooling under operational states and design basis accidents. Because these are straightforward measurements, neither IEC SC 45A nor IEEE NPEC considered that a standard on this topic was necessary. During the accident at Fukushima Daiichi, explosions occurred in the reactor buildings of units 1, 3, and 4. Hydrogen release from fuel in the spent fuel pool, due to loss of water inventory, had to be considered as a possible cause of the explosions. Instrument

Scope: 1.1 General This document provides criteria for spent fuel pool instrumentation for nuclear power generating stations and other nuclear facilities. The document applies to water filled spent fuel pools where the water volume is necessary to prevent a release of fission products that exceeds allowed operational limits. 1.2 Purpose The purpose of this document is to establish design, performance, qualification, and display criteria for spent fuel pool instrumentation for normal operation, anticipated operational occurrences, design basis events, and design extension conditions (including severe accident conditions). 1.3 Application This document applies only to instrumentation for monitoring the condition of the spent fuel pool, i.e., pool level, pool temperature, and area radiation. It does not apply to control systems that are related to the spent fuel pool such as: the pool cooling systems, isolation valve control, crane instrumentation and control, or refuelling machine instrumentation and control. In some plant designs some of the instruments covered by this document also provide inputs to protection system functions. Such instruments must also comply with requirements for protection systems that are given elsewhere. The requirements applied to the systems and components performing these functions depend on how they contribute to the safety of the spent fuel pool.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC/IEEE 63113-2021 PDF

IEC/IEEE 63113-2021 PDF

$132.41 $264.81