IEC TR 60344-2007 PDF

IEC TR 60344-2007 PDF

Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires-Application guide

$12.61 $25.22 -50%
Product Code: IEC TR 60344
Stock In Stock
Edition: 3.0
Published: 02/2007
Number of Pages: 10
File Size: 0 files

Available Options

Product Description

Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires – Application guide

Scope: This Technical Report applies to low-frequency cables and wires for telecommunication and gives a general method for calculating the resistance of copper conductors. General method of calculation The maximum conductor resistance, R, at 20 °C of insulated copper conductors is equal to R = R0 k1 k2 k3 k4 Ω/km where nd is the number of strands in the conductor (for a solid conductor n = 1); is the nominal diameter of the strands in the conductor, in millimetres, or, for a solid conductor, its nominal diameter; k1 is a factor depending on the diameter of the strands and on plain or coated conductor. Values for k1 are given in Table 1; k2 is a factor depending on the type of conductor; the value is equal to 1,00 for solid conductors; 1,04 for stranded conductors; k3 is a twisting factor depending on conductor dimension and the way the insulated conductors are twisted together (for single wires k3 = 1). Values for k3 are given in Table 2; k4 is, for cabIes with more than one cabling element, a cabling factor depending on conductor size and on the way the cabling elements are assembled, or, for cables with one cabling element and for screened wires up to and including five insulated conductors, an elongation factor depending on conductor size. VaIues for k4 are given in Table 3. Values of R are given in Table 4. These values are calculated with different coefficients k1, k2, k3, k4. The result of the calculations is given with six significant figures. In publications, the value chosen in this table shall be indicated with three significant figures for R below 1 000, and four significant figures from 1 000; for this the table value shall be rounded off to the nearest value. NOTE The copper conductivity is 58 m/Ωmm².

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 60344-2007 PDF

IEC TR 60344-2007 PDF

$12.61 $25.22