IEC TR 61141-1992 PDF

IEC TR 61141-1992 PDF

Upper Frequency Limit of R.F. Coaxial Connectors

$100.88 $201.76 -50%
Product Code: IEC TR 61141
Stock In Stock
Edition: 1.0
Published: 03/1992
Number of Pages: 48
File Size: 1 file, 1 Byte

Available Options

Product Description

Upper Frequency Limit of R.F. Coaxial Connectors

Introduction: Coaxial connectors are used in large numbers. With the extension of coaxial connectors and air lines to higher frequencies, the geometric dimensions of connectors are selected in such a manner to preclude the propagation of higher order modes. In principle, electromagnetic energy may be propagated in coaxial lines in the TEM (transverse electro- magnetic) mode at any frequency. Higher order modes may be excited in the line besides the fundamental TEM mode with changes in geometric dimensions, addition of support beads, thickness of the beads and their dielectric constant along with changes in characteristic impedance. It has been common practice to specify the upper frequency limit for a given coaxial air line as the calculated frequency at which the next higher mode above the TEM mode (TE 11 )* would propagate in a coaxial air line. With the addition of dielectric bead supports, the TE 1t mode can be excited below this frequency. Higher mode resonance effects of dielectric beads in coaxial air lines have been described (see references [1] to [4]"). A resonator model has been derived which gives a theoretical description of resonance conditions (see reference [5]). Direct measurements of higher mode resonances in bead supported coaxial air lines are necessary to estimate the upper frequency limit of r.f. coaxial connectors. Experience shows that with dielectric bead supports having perfect symmetry, higher order modes are not readily generated even if existing conditions are

Scope: This Technical Report presents two measurement methods for determining the first possible higher order mode (non TEM) of r.f. connector beads, connectors and pairs of connectors. One method is a transmission measurement technique and the other is an automated reflection measurement technique. Both techniques were used to determine the resonances of different coaxial connectors. Results from both techniques are included. This report gives resonant frequency plots for 7 mm, 3,5 mm, 2,9 mm, 2,4 mm, 2,0 mm, SMA and type N coaxial connectors, plus references to applicable articles.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 61141-1992 PDF

IEC TR 61141-1992 PDF

$100.88 $201.76