IEC TR 61243-6-2017 PDF

IEC TR 61243-6-2017 PDF

Live working - Voltage detectors - Part 6: Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC

$163.93 $327.86 -50%
Product Code: IEC TR 61243-6
Stock In Stock
Edition: 1.0
Published: 03/2017
Number of Pages: 44
File Size: 1 file, 999 Bytes

Available Options

Product Description

Live working - Voltage detectors - Part 6: Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC

Introduction: With the aim of ensuring the safety of the users the purpose of a voltage detector is to give a clear indication of the presence or absence of the operating voltage, without any need for interpretation or analytical evaluation by the user. IEC 61243-1, IEC 61243-2 and IEC 61243-3 apply to portable voltage detectors designed to work correctly when they are in direct contact with the bare part of the installation to be tested. At HV and UHV, large distances between the user and the bare parts to be tested make the handling of a very long insulating element or insulating stick an ergonomic and safety concern. In such situations, it may become convenient to avoid any contact with the bare part to be tested and to perform voltage detection at a distance. This document provides considerations and performance guidelines for portable “non-contact” voltage detectors and it can be used as a reference for the development of national, industry or manufacturer's standard(s) or for the selection of a product by users. This document has been prepared taking into consideration the provisions given in IEC 61477.

Scope: This part of IEC 61243, which is a Technical Report, is applicable to portable non-contact voltage detectors (NCVD) with built-in power source, to be used to indicate the presence or the absence of the operating voltage on electrical systems for nominal voltages above 1 kV AC and frequencies of 16 2/3 Hz, 50 Hz and/or 60 Hz. NOTE 16,7 Hz is often referenced. This document applies only to devices that are not designed to be used in contact with the bare part of the installation on which the presence or the absence of the operating voltage has to be tested. This document describes only devices, and their behaviour, using electric field and voltage gradient detection principles even if other principles could be used. It provides performance guidelines, recommendations for use and recommended minimum criteria for selection. Devices like personal safety distance voltage detectors, distance voltage detectors for emergency responders or machine operators are not covered by this document. Except when otherwise specified, all the voltages defined in this document refer to phase-to- phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages are used to determine the operating voltage.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope