High-voltage direct current (HVDC) systems – Guidance to the specification and design evaluation of AC filters – Part 5: AC side harmonics and appropriate harmonic limits for HVDC systems with voltage sourced converters (VSC)
Introduction: The IEC TR 62001 series is structured in five parts: IEC TR 62001-1 – Overview This part concerns specifications of AC filters for high-voltage direct current (HVDC) systems with line-commutated converters, permissible distortion limits, harmonic generation, filter arrangements, filter performance calculation, filter switching and reactive power management and customer specified parameters and requirements. IEC TR 62001-2 – Performance This part deals with current-based interference criteria, field measurements and verification. IEC TR 62001-3 – Modelling This part addresses the harmonic interaction across converters, pre-existing harmonics, AC network impedance modelling, simulation of AC filter performance. IEC TR 62001-4 – Equipment This part concerns steady-state and transient ratings of AC filters and their components, power losses, audible noise, design issues and special applications, filter protection, seismic requirements, equipment design and test parameters. IEC TR 62001-5 – AC side harmonics and appropriate harmonic limits for high-voltage direct current (HVDC) systems with voltage sourced converters (VSC) This part concerns specific issues of AC filter design related to VSC HVDC systems. The rapid proliferation, increasing power, and technical advances of voltage source converter (VSC) HVDC technology in recent years has had a revolutionary impact on large-scale electrical power transmission. In the sphere of harmonics and filtering, the introduction of VSC techn
Scope: This part of IEC TR 62001, which is a Technical Report, provides guidance on the state-of-the art of VSC technology in relation to harmonics and predicted future developments, on the harmonic profile of present and predicted future VSC architectures and how they are characterised and modelled – as voltage sources, current sources, or otherwise. It also assesses the harmonic impedance of VSC and the possible impact on pre-existing background harmonics emanating from loads or generation units in the supply network and considers how VSC harmonics are assessed under current IEC standards and national regulations, and identify areas where improvements could be made, research can be needed, or other bodies consulted, for example when considering interharmonics. This document can be a reference source on the subject, which will also contain recommendations for use by those charged with modifying existing standards to adapt to VSC HVDC systems. Issues relating to harmonics on the DC side of the converters, including DC grids, are deliberately not covered in this document, but are addressed by a separate CIGRE Technical Brochure [1]1.
Contents:
- FOREWORD
- INTRODUCTION
- Scope