Electrical steel – Methods of measurement of the magnetostriction characteristics by means of single sheet and Epstein test specimens
Introduction: Magnetostriction is one of the magnetic properties that accompany ferromagnetism. It causes reversible deformations of a material body due to magnetization arising from an applied magnetic field. Nowadays, the environmental problem of acoustic noise pollution caused by transformers and other applications of electrical steels (e.g. ballast, motors, etc.) is a concern of industry [31]1. Magnetostriction of electrical steels is recognized as one of the causes of the problem and a standardization of methods of measurement of the magnetostriction is required to advance developments in materials to address this problem. Historically, several methods have been used to measure magnetostriction including strain gauge, capacitance, differential transformer, piezoelectric pick-up and piezoelectric accelerometer methods. However, these methods require skill to set up the sensor accurately and to avoid vibrational noise that accompanies these contact methods. To solve these problems, optical methods that adopt optical vibrometers and optical displacement meters have been developed [1]-[8]. The optical method satisfies the following requirements for the measurement: non-contact, high resolution, high reproducibility and ease of operation without any special skill on the part of the operator. Several optical sensors can be used: laser Doppler vibrometers, heterodyne displacement meters and laser displacement meters with high resolution. Magnetostriction is a magneto-mechanical phenomenon wh
Scope: This technical report describes the general principles and technical details of the measurement of the magnetostriction of single sheet specimens preferably 500 mm long and 100 mm wide and Epstein strip specimens, specified in IEC 60404-2, of electrical steel by means of optical sensors and accelerometers. These methods are applicable to test specimens obtained from electrical steel sheets and strips of any grade. The characteristics of magnetostriction are determined for a sinusoidal induced voltage, for specified peak values of magnetic polarization and for a specified frequency. The measurements are made at an ambient temperature of 23 °C ± 5 °C on test specimens which have first been demagnetized.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 4.10 Data processing
- 4.11 Preparation for measurement
- 4.12 Adjustment of power supply
- 4.13 Measurement
- 4.14 Determination of the butterfly loop
- 4.15 Determinations of the zero-to-peak and peak-to-peak values
- 4.16 Reproducibility