Low-voltage switchgear and controlgear - Fire risk analysis and risk reduction measures

Introduction: As fire-ignition hazards are inherent with electricity, installation rules and product standards for electrical equipment are aimed at providing risk reduction measures and minimizing residual risk without compromising product safety and function. Residual risk of low-voltage switchgear and controlgear compliant with IEC 60947 relevant publications is generally low and, when selected, installed and used according to manufacturer instruction and installation rules, do not ignite fire in normal operation or reasonably foreseeable fault conditions. This document, in accordance to ISO/IEC Guide 51 and IEC Guide 116, describes the fire risk analysis of electrical equipment and risk reduction measures in IEC 60947 relevant publications. While intended to apply specifically to low voltage switchgear and controlgear, it is suggested that other product committees may find this information useful. The fire hazards, namely the flame ignition mechanisms, relevant for low-voltage switchgear and controlgear are reviewed and discussed. The related risk reduction measures included in IEC 60947 relevant publications are subsequently reported for each of those mechanisms. These measures are based on a system approach, not limited to construction materials requirements and include design rules and type testing to ensure equipment do not cause fires in normal operation or due to reasonably foreseeable faulty conditions.

Scope: This document applies to the fire risk analysis of low-voltage switchgear and controlgear (hereinafter referred to as "equipment") referring to the IEC 60947 relevant publications, where the following applies: only the case where a fire originates (typically under fault or misuse conditions) within the equipment; only equipment installed in normal environments. Hazardous environments, for example in presence of combustible materials, is not to be considered; only the case of products selected, installed and used according to the manufacturer instructions and installation rules. In addition, the following cases are not considered: faults addressed by IEC TR 61641; risks due to smoke emissions; double faults, i.e. multiple phenomenon, potentially combined.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope