Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 2: Method for determining the electrical resistivity of dust in layers
Introduction: This technical repo rt is applicable to the determination of the electrical resistivity of dust in layers. The test method is not suitable for use with recognized explosives, gunpowder, dynamite, or substances or mixtures of substances which may, under some circumstances, behave in a similar manner. Where any doubt exists about the existence of a hazard due to explosive properties, an indication may be obtained by placing a very small quantity of the dust in question on the heated surface of the apparatus prescribed in IEC 1241-2-1*, heated to 400 °C. The test for explosivity will not always reveal the explosive nature of a dust so that a "fail to danger* situation could arise. NOTE - Precautions should be taken to safeguard the health of personnel conducting the tests against the risk of fire, explosion and/or the effects, including toxic effects, of combustion. This test method is applicable to the construction and application of electrical apparatus for use in the presence of combustible dust. * IEC 1241-2-1: 1993, Electrical apparatus for use in the presence of combustible dust – Part 2: Test methods – Section 1 (under consideration).
Scope: This technical report specifies a method of test to determine, by application of a d.c. voltage, the electrical resistivity of a layer of dust. It is intended to be used in the design, construction, testing, and application of electrical apparatus for use in the presence of combustible dust. The test method is not suitable for use with recognized explosives or substances having explosive properties.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 4 Test apparatus
- 5 Test sample
- 6 Procedure
- 6.2 Measurement of resistance