Electrical insulating materials and systems – Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses
Introduction: Power electronics has been developed along with both control theory and semiconductor technology. Switching is one of the essential features of power electronics control. For higher efficiency and smoother operation, switching times of the latest devices such as an insulated- gate bipolar transistor (IGBT) tend to be shorter than microseconds. The introduction of wide band gap devices, such as those based on silicon carbide, can result in transients with rise times of the order of a few tens of nanoseconds. Such a short rise time may can cause transient overvoltage impulses or surges in systems. When the voltage impulses reach the breakdown strength of an air gap, partial discharge (PD) may can occur. In addition, the impulses are repetitive from power electronics modulation such as pulse width modulation (PWM). Since PD may can cause degradation of electrical insulation parts in the system, it is one of the most important parameters to be measured. The first edition of IEC TS 61934 was issued in April 2006. Because of rapid development in this field, the revision activity for the latest information was approved by TC 112 at their Berlin meeting in September 2006. In addition to technical and editorial changes, practical experience obtained through round-robin test (RRT) is also presented in Annex C. The second edition of IEC TS 61934 was published in 2011. Owing to further advances in this area, a revision of the second edition was commenced formally in 2019 and has resulted
Scope: This document is applicable to the off-line electrical measurement of partial discharges (PDs) that occur in electrical insulation systems (EISs) when stressed by repetitive voltage impulses generated from electronic power electronics devices. Typical applications are EISs belonging to apparatus driven by power electronics, such as motors, inductive reactors and windmill, wind turbine generators and the power electronics modules themselves. NOTE 1 Use of this document with specific products may can require the application of additional procedures. NOTE 2 The procedures described in this technical specification are emerging technologies. Experience and caution, as well as certain preconditions, are needed to apply it. Excluded from the scope of this document are methods based on optical or ultrasonic PD detection, fields of application for PD measurements when stressed by non-repetitive impulse voltages such as lightning impulse or switching impulses from switchgear.
Contents:
- FOREWORD
- INTRODUCTION
- Scope