IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures
Introduction: This document provides a standard set of methods and procedures for determining the shielding effectiveness (SE) of shielding enclosures. The enclosures of concern include those used for testing groups of equipment, vehicles, computing systems, and smaller units whose electromagnetic (EM) emission and susceptibility require determination without disturbance from other sources. This standard incorporates the basic concepts of MIL-STD-285,a the SE measurement reference for many years, which was cancelled by the U.S. Department of Defense in 1997. Those concepts have been expanded upon to increase the applicability of the measurement techniques to enclosures having a wide variety of applications and constructed from a large number of materials with varying methods of fabrication and assembly. The basic premise of MIL-STD-285 is still in position: the shield effect is to provide an insertion loss to outside influence. IEEE Std 299-2006 offers testing based upon the performance specifications of the shield, rather than a fixed set of parameters that may not be applicable to the shield in question. The specific test procedures and frequency ranges are selected as appropriate for the enclosure being tested. The most important factor considered during the development of this revision was the concept that measurement of EM SE is a requirement not unique to walk-in sized enclosures. There are no widely accepted standards in use to describe test methods and techniques for measuring SE o
Scope: This standard provides uniform measurement procedures for determining the effectiveness of electromagnetic (EM) shielding enclosures at frequencies from 9 kHz to 18 GHz (extendable down to 50 Hz and up to 100 GHz). The owner of the shielding enclosure shall provide the frequencies at which the shield will be tested, and the shielding effectiveness (SE) limits for pass/fail. This standard suggests a range of test frequencies that would provide very high confidence in the effectiveness of the shield. This standard dose not define SE limits for pass or fail. Purpose The purpose of this standard is to provide the following: a) A standard procedure for the measurement of the effectiveness of shielded enclosures, in a broad range of radio frequencies (RFs), including a minimum set of recommended frequencies b) Identical procedures applicable to frequencies other than the standard set c) An optional measurement technique to detect the nonlinear behavior of high-permeability ferromagnetic enclosures (see Annex C) Application The measurement procedures provided in this standard apply to any enclosure having a smallest linear dimension greater than or equal to 2.0 m. Separate methods, to be provided in the future, shall be used for enclosures with any dimension smaller than 2.0 m. In the case of enclosures that are to be used in anechoic or semianechoic applications, this procedure shall apply prior to the installation of any RF absorber materials. Copyright © 2007 IEEE. All rights reserved.
Contents:
- 1.1 Scope
- 1.2 Purpose
- 1.3 Application
- 3.1 General terminology
- 3.2 Technical terminology
- 4.1 Background
- 4.2 Test plan
- 4.3 Calibration
- 4.4 Reference level and dynamic range
- 4.5 Preliminary shield check procedures
- 4.6 Test/witness personnel
- 5.1 Background
- 5.2 Recommended standard measurement frequencies
- 5.3 Pass/fail requirements
- 5.4 Shielding effectiveness calculation
- 5.5 Preparation procedures
- 5.6 Low-frequency measurements (9 kHz to 20 MHz)
- 5.7 Resonant range measurements (20 MHz to 300 MHz)
- 5.8 High-frequency measurements (300 MHz to 18 GHz)
- 6.1 Abbreviated test report
- 6.2 Full test report