IEEE Guide for the Application of Tertiary and Stabilizing Windings in Power Transformers
Introduction: This introduction is not part of IEEE Std C57.158-2017, IEEE Guide for the Application of Tertiary and Stabilizing Windings in Power Transformers. In all mature industries, as for instance the electric power supply industry, there is always a knowledge that is commonly applied, even though its fundamentals have not been summarized in a single, comprehensive source. In most cases, impact of such “missing links” is very minor, and more important issues become privileged for development into standards, as resources are naturally scarce. This document deals with the subject of application of stabilizing windings in modern electric power systems, where some issues with wye-wye-connected transformers emerging in the early days were solved with practical sense by adding extra components in transformers, without an exact account of all real and potential benefits. Part of the fundamentals for those applications is a tacit, empirical knowledge, with arbitrary interpretations of successful or unsuccessful events giving rise to a series of “rules,” from which very different versions are implemented. The purpose of this document is, first, to synthesize the fundamentals for contemporary application of a technical solution, and second, to review and present to the industry a more organized set of application rules and recommendations. The IEEE working group that developed this application guide started working as a task force in 2009, and originally developed a proposed new subclause 5.11
Contents:
- 1.1 Scope
- 1.2 Purpose
- 4.1 Wye-wye-connected transformers
- 4.2 Application of stabilizing windings, from the perspective of power system design and operation
- 4.3 Application of stabilizing windings from perspective of transformers performance
- 5.1 How stabilizing windings function
- 5.2 When is a stabilizing winding required?
- 5.3 Sizing a stabilizing winding
- 5.4 Short-circuit and continuous rating of tertiary windings
- 6.1 Network interconnection transformers and autotransformers
- 6.2 Primary substation power transformers
- 6.3 Wind farm collector transformers (three phase)
- 6.4 Grounding of wye-wye transformers’ neutrals
- 6.5 Some special practice from utilities
- 7.1 Short-circuit currents
- 7.2 Short-circuit stresses
- 7.3 Calculation of short-circuit currents for line-to-ground faults
- 7.4 Short-circuit current calculation report for a wye-wye-delta transformer
- 7.5 Consequences from specifying high short-circuit power for MV networks
- 7.6 Paralleling of transformers and autotransformers with and without tertiary or stabilizing windings 56
- 7.7 Application of current-limiting reactors on stabilizing and tertiary windings
- 8.1 Behavior under transient conditions
- 8.2 Currents and voltages on wye-wye-connected transformers and autotransformers, subjected to
- 8.3 Behavior of transformers and autotransformers without stabilizing or tertiary winding
- 9.1 Specification of tertiary and stabilizing windings
- 9.2 Testing of tertiary windings
- 9.3 Testing of stabilizing windings
- 9.4 Selection of stabilizing winding voltage rating