IEEE C62.39-2012 PDF

IEEE C62.39-2012 PDF

IEEE Standard for Test Methods and Preferred Values for Self-Restoring Current-Limiter Components Used in Telecommunication Surge Protection

$43.50 $87.00 -50%
isbn 9780738180410
Product Code: IEEE C62.39
Stock In Stock
Published: 01/14/2013
Number of Pages: 39
File Size: 1 file, 500 KB

Available Options

Product Description

IEEE Standard for Test Methods and Preferred Values for Self-Restoring Current-Limiter Components Used in Telecommunication Surge Protection

Introduction: This introduction is not part of IEEE Std C62.39-2012, IEEE Standard for Test Methods and Preferred Values for Self- Restoring Current-Limiter Components Used in Telecommunication Surge Protection. Unlike fuses and heat coils, self-restoring overcurrent protectors (OCPs) automatically reset after the end of the overcurrent condition without the need for manual intervention. All the OCPs covered in this standard are solid-state. Having no moving parts these OCPs are more reliable than thermal circuit breakers and mechanical disk switches. The current reducing action is for the normally low (untripped) OCP resistance to transition to a very high tripped resistance value, which greatly reduces the circuit current flow. The positive temperature coefficient (PTC) thermistor OCPs transition is caused by the component body reaching a critical temperature. The body temperature rise is caused by the i2R heating of the overcurrent flowing through the component. Being thermally operated PTC thermistor OCPs do not operate for short duration lightning currents, but for ac overcurrents caused by power faults. Electronic current limiter (ECL) OCPs operate on a preset current threshold level and will reduce both ac and lightning overcurrents to that threshold current level. Under lightning surge conditions both OCP types assist in the protection coordination function. These OCPs will have untripped resistance values ranging from a few ohms to some 50 Ω. This series resistance provides a coor

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 2.1 Definitions
  • 2.2 Acronyms
  • 5.1 Test methods
  • 5.2 Electrical requirements
  • 6.1 Resistance, R
  • 6.2 Hold current, Ih
  • 6.3 Trip current, It
  • 7.1 Time-to-trip, ttrip (PTC thermistor)
  • 7.2 Resistance 1 h after tripping, R1 for PPTC thermistors
  • 7.3 Reset voltage, Vreset for ECL
  • 7.4 Impulse resistance, Rimp, for ceramic PTC thermistors
  • 8.1 Impulse voltage withstand
  • 8.2 AC power fault—power induction tests
  • 8.3 AC power fault—power contact tests
  • 8.4 Impulse endurance test (life test)
  • 8.5 AC endurance test (life test)
  • 9.1 Hold current variation with temperature
  • 9.2 Trip-time variation with fault current value for PTC thermistor OCPs
  • 9.3 Resistance recovery after a trip event for PPTC thermistor OCPs

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE C62.39-2012 PDF

IEEE C62.39-2012 PDF

$43.50 $87.00