ISO 20289-2025 PDF

ISO 20289-2025 PDF

Surface chemical analysis-Total reflection X-ray fluorescence analysis of water

$96.50 $193.00 -50%
Product Code: ISO 20289
Stock In Stock
Edition: 2.
Published: 06/2025
Number of Pages: 26
File Size: 1 file, 2 Bytes

Available Options

Product Description

Surface chemical analysis — Total reflection X-ray fluorescence analysis of water

Introduction: Total reflection X-ray fluorescence (TXRF) spectroscopy is a surface sensitive technique which can be used to obtain compositional information about different kinds of samples. ISO/TS 18507 provides guidelines for the characterization of biological and environmental samples with TXRF. TXRF is suitable for quantitative elemental analysis of liquid samples deposited as thin films on clean and well-polished reflectors, by means of internal standard calibration[1][2]. This document provides guidance and requirements for the quantitative elemental analysis of water by means of TXRF instrumentation. © ISO 2025 – All rights reserved

Scope: This document specifies a chemical method for technicians working with total reflection X-ray fluorescence (TXRF) instrumentation to perform measurements of water samples, according to good practices, with a defined degree of accuracy and precision. Target users are identified among laboratories performing routine analysis of large numbers of samples, which also conform with ISO/IEC 17025. This document specifies a method to determine the content of elements dissolved in water (e.g. drinking water, surface water and ground water). This document is also applicable for determining elements in waste waters and eluates, taking into account the specific and additionally occurring interferences. This document does not specify sampling, dilution and pre-concentration methods. Elements determined using the method specified in this document can depend on the X-ray source of the instrument. This document does not specify health, safety or commercial aspects. The determinable concentrations depend on the matrix and the interferences encountered. In drinking water and relatively unpolluted waters, the limit of quantification lies between 0,001 mg/l and 0,01 mg/l for most of the elements. The range of concentrations typically lies between 0,001 mg/l and 10 mg/l, depending on the element and predefined requirements. Annex A reports an example of uncertainty calculation. Annex B provides an example report on validation of the method for TXRF analysis of water performed with instrumentation that has Mo as the X-ray source and uses Ga as the internal calibration standard. Limits of quantification of most elements are affected by blank contamination and depend predominantly on the laboratory air-handling facilities available, on the purity of reagents and the cleanliness of labware.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 20289-2025 PDF

ISO 20289-2025 PDF

$96.50 $193.00