ISO 13165-1-2022 PDF

ISO 13165-1-2022 PDF

Water quality-Radium-226-Part 1: Test method using liquid scintillation counting

$71.50 $143.00 -50%
Product Code: ISO 13165-1
Stock In Stock
Edition: 2.
Published: 11/2022
Number of Pages: 22
File Size: 1 file, 1 Byte

Available Options

Product Description

Water quality — Radium-226 — Part 1: Test method using liquid scintillation counting

Introduction: Radioactivity from several naturally-occurring and anthropogenic sources is present throughout the environment. Thus, water bodies (such as surface waters, ground waters, sea waters) can contain radionuclides of natural, human-made, or both origins. — Natural radionuclides, including 40K, 3H, 14C, and those originating from the thorium and uranium decay series, in particular 226Ra, 228Ra, 234U, 238U, 210Po and 210Pb can be found in water for natural reasons (e.g. desorption from the soil and washoff by rain water) or can be released from technological processes involving naturally occurring radioactive materials (e.g. the mining and processing of mineral sands or phosphate fertilizers production and use). — Anthropogenic radionuclides such as transuranium elements (americium, plutonium, neptunium, curium), 3H, 14C, 90Sr and gamma emitting radionuclides can also be found in natural waters. Small quantities of these radionuclides are discharged from nuclear fuel cycle facilities into the environment as a result of authorized routine releases. Some of these radionuclides used for medical and industrial applications are also released into the environment after use. Anthropogenic radionuclides are also found in waters as a result of past fallout contaminations resulting from the explosion in the atmosphere of nuclear devices and accidents such as those that occurred in Chernobyl and Fukushima. Radionuclide activity concentration in water bodies can vary according to local geologic

Scope: This document specifies the determination of radium-226 (226Ra) activity concentration in non-saline water samples by extraction of its daughter radon-222 (222Rn) and its measurement using liquid scintillation analysis. The test method described in this document, using currently available scintillation counters, has a detection limit of approximately 50 mBq·l−1. This method is not applicable to the measurement of other radium isotopes.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 13165-1-2022 PDF

ISO 13165-1-2022 PDF

$71.50 $143.00