Reaction-to-fire tests for sandwich panel building systems-Part 2: Test method for large rooms

$71.50 $143.00 -50%
Product Code: ISO 13784-2
Stock In Stock
Edition: 2ND
Published: 10/2020
Number of Pages: 24
File Size: 1 file, 1 Byte

Available Options

Product Description

Reaction-to-fire tests for sandwich panel building systems — Part 2: Test method for large rooms

Introduction: Fire is a complex phenomenon, its behaviour and effects dependent upon a number of interrelated factors. The behaviour of materials and products depends upon the characteristics of the fire, the method of use of the materials and the environment in which they are exposed (for the philosophy of reaction-to-fire tests, see ISO/TS 3814). The need for improved insulation of buildings has led to the increased use of thermal insulating sandwich panel systems in different parts of the building industry. Thermal insulating sandwich panel systems are applied as external cladding on factory buildings, in internal envelopes with controlled atmospheres and in cold stores, varying from small rooms to large, coolhouses and warehouses. Other applications are in modular building rooms and retail premises. These systems can also be used for roof applications in traditional constructions. Multi-layered panels with other facings (e.g. plasterboard) or sandwich panel systems can also be applied to walls as internal linings or insulation; however, this is not within the scope of the ISO 13784 series. There exist three primary fire-related threats to the walls and ceilings or roofs of a building insulated with freestanding or frame-supported types of thermal insulating sandwich panel systems: a) an interior compartment fire impinging directly onto the joints of the wall, typical ignition sources being welding torches, burning items near the wall and fire in an adjacent room; b) an external fire or

Scope: This document specifies a test method for evaluating the reaction-to-fire performance of thermal insulating sandwich panel building systems for large rooms and the resulting flame spread on or within the thermal insulating sandwich panel building construction when it is exposed to heat from a simulated internal fire with flames impinging directly on its internal corner. The test method is not intended for evaluating a product's fire resistance. This document is applicable to both freestanding and self-supporting and frame-supported thermal insulating sandwich panel systems, but only to wall and ceiling or roof constructions.

Be the first to write a review for this product.