ISO 15106-7-2015 PDF

ISO 15106-7-2015 PDF

Plastics - Film and sheeting - Determination of water vapour transmission rate - Part 7: Calcium corrosion method

$48.00 $96.00 -50%
Product Code: ISO 15106-7
Stock In Stock
Edition: 1ST
Published: 04/15/2015
Number of Pages: 16
File Size: 1 file, 316 Bytes

Available Options

Product Description

Plastics - Film and sheeting - Determination of water vapour transmission rate - Part 7: Calcium corrosion method

Scope: This part of ISO 15106 specifies a method for determining the water vapour transmission rate of plastic film, plastic sheeting, and multi-layer structures including plastics based on measurements of calcium degradation due to the reaction with water. NOTE The method provides rapid measurement over a wide range of water vapour transmission rates. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 water vapour transmission rate amount of water vapour transmitted through unit area of test specimen per unit time under specified conditions Note 1 to entry: Water vapour transmission rate is expressed in grams per square metre per 24 h [g/(m2∙24 h)]. 2.2 seal material adhesive materials between test specimen and glass slide for protecting the calcium film from the corrosive gas 2.3 encapsulant encapsulation material for protecting the calcium film from the corrosive gas 3 Principle The calcium test method is based on measuring the rate of reaction between calcium metal and water. A calcium film is deposited on a test specimen or a glass slide and sealed or encapsulated according to one of the three procedures described in Annex A, Annex B, and Annex C. The water vapour transmission rate is determined from the change of calcium film properties after exposure in an environmental chamber as described in Annex A, Annex B, and Annex C. 4 Test specimens 4.1 The test specimens shall be representative of the material, free from wrinkles, creases and pinholes, and have uniform thickness. Each test specimen shall have a larger area than the transmission area of the cell. 4.2 Three test specimens shall be tested unless otherwise specified or agreed between the interested parties. NOTE For some products, testing more than three test specimens gives a more representative result. INTERNATIONAL STANDARD ISO 15106-7:2015(E) © ISO 2015 – All rights reserved

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 15106-7-2015 PDF

ISO 15106-7-2015 PDF

$48.00 $96.00