ISO 16000-38-2019 PDF

ISO 16000-38-2019 PDF

Indoor air - Part 38: Determination of amines in indoor and test chamber air - Active sampling on samplers containing phosphoric acid impregnated filters

$48.00 $96.00 -50%
Product Code: ISO 16000-38
Stock In Stock
Edition: 1ST
Published: 02/2019
Number of Pages: 16
File Size: 1 file, 1 Byte

Available Options

Product Description

Indoor air - Part 38: Determination of amines in indoor and test chamber air - Active sampling on samplers containing phosphoric acid impregnated filters

Introduction: ISO 16000 (all parts) describe general requirements relating to the measurement of indoor air pollutants and the important conditions to be observed before or during the sampling of individual pollutants or groups of pollutants, as well as the measurements procedures themselves. The definition of indoor environment is given by ISO 16000-1. Dwellings [living rooms, bedrooms, do- it-yourself (DIY) rooms, sport rooms and cellars, kitchens and bathrooms], workrooms or workplaces in buildings which are not subject to health and safety inspections with respect to air pollutants (e.g. offices, salesrooms), public buildings (e.g. restaurants, theatres, cinemas and other meeting rooms) and passenger cabins of motor vehicles and public transportation are among the most important types of indoor environment. © ISO 2019 – All rights reserved

Scope: This document specifies a method for the determination of primary, secondary and tertiary aliphatic and aromatic amines in indoor air using accumulated sampling and high-performance liquid- chromatography (HPLC) coupled with tandem mass spectrometry (MS-MS) or high resolution mass spectrometry (HRMS). It specifies the sampling procedure for determining the mass concentration of amines as mean values by sampling the amines on phosphoric acid impregnated filters. The analytical procedure of the measurement method is covered by ISO 16000-39. Measurements, performed with samplers containing phosphoric acid-impregnated inert supporting material and operating at specified flow rates for specified sampling periods are described in this document. Requirements regarding sample volume are also defined. The range of application of this document concerning the concentrations of amines in indoor air depends on the linear range of the calibration line and hence on the gas sample volume (here: from 5 l up to 100 l), the eluate volume (from 1 ml up to 5 ml), the injection volume (from 1 µl up to 10 µl) and the sensitivity of the analytical equipment (e.g. linear range from 2 pg up to 2 ng amine). The range of application can be expected to be from approximately 0,002 µg/m3 (100 l sample) up to 2 000 µg/m3 (5 l sample) for a common analytical equipment1) for the majority of the amines listed in Annex A. The analysis of derivatives of ethanolamine is usually about 10 times more sensitive and the analysis of short-chained aliphatic amines is usually about 10 times less sensitive than the analysis of an average amine. Although primarily intended for the measurement of amines listed in Annex A, this document can also be used for the measurement of other amines in indoor air. This document describes procedures for the fabrication and gives requirements for the use of glass tubes containing impregnated filters out of phosphoric acid-impregnated glass wool as samplers, but does not exclude other samplers with proven equal or improved properties. This document also gives procedures for the demonstration of equivalence of other sampler types or methods. This document does not cover the d

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16000-38-2019 PDF

ISO 16000-38-2019 PDF

$48.00 $96.00