Plastics piping systems for the supply of gaseous fuels — Unplasticized polyamide (PA-U) piping systems with fusion jointing and mechanical jointing — Part 4: Valves
Introduction: This document specifies the requirements for valves used in a piping system made from unplasticized polyamide (PA-U) that is intended to be used for the supply of gaseous fuels. General requirements for unplasticized polyamide (PA-U) materials used for a piping system and its components, intended for the supply of gaseous fuels, are specified in ISO 16486-1. Requirements and test methods for pipes are specified in ISO 16486-2 and for fittings in ISO 16486-3. Characteristics for fitness for purpose of the system and generic fusion parameters are specified in ISO 16486-5. Recommended practice for installation is given in ISO 16486-6, which will not be implemented as a European standard under the Vienna Agreement. NOTE 1 Recommended practice for installation is also given in CEN/TS 12007-6, which has been prepared by Technical Committee CEN/TC 234, Gas infrastructure. Assessment of conformity of the system is given in ISO/TS 16486-7. Training and assessment of fusion operators is covered by ISO/TS 16486-8. NOTE 2 For CEN member countries, the recommended practice for installation is given in CEN/TS 12007-6 and the qualification of welders is given by EN 13067.[5] ISO 16486-1, ISO 16486-2, ISO 16486-3, ISO 16486-5 and ISO 16486-6 as well as ISO/TS 16486-7 and ISO/TS 16486-8 have been prepared by ISO/TC 138/SC 4. ISO 16486-4 (this document) has been prepared by ISO/TC 138/SC 7. NOTE 3 For conformance of components in CEN member countries, relevant EN standards can apply. Alternati
Scope: This document specifies the characteristics of valves made from unplasticized polyamide (PA-U) in accordance with ISO 16486-1, intended to be buried and used for the supply of gaseous fuels. NOTE 1 For the purpose of this document the term gaseous fuels include for example natural gas, methane, butane, propane, hydrogen, manufactured gas, biogas, and mixtures of these gases. Additional information about the suitability for 100 % hydrogen and its admixtures with natural gas is given by ISO 16486-1:2023, Annex C and Annex D. It is applicable to isolating unidirectional and bi-directional valves with spigot ends or electrofusion sockets intended to be fused with PA-U pipes conforming to ISO 16486-2 and PA-U fittings conforming to ISO 16486-3. This document also specifies the test parameters for the test methods it describes. In conjunction with ISO 16486-1, ISO 16486-2, ISO 16486-3 and ISO 16486-5, this document is applicable to PA-U valves and their joints and to joints with components of PA-U and other materials intended to be used under the following conditions: a) a maximum operating pressure (MOP) of up to and including 18 bar1), or limited to 16 bar under regional CEN requirements, at a reference temperature of 20 °C for design purposes; NOTE 2 For the purpose of this document and the references to ISO 8233, MOP is considered to be nominal pressure. b) an operating temperature of −20 °C to 40 °C; NOTE 3 For operating temperatures between 20 °C and 40 °C, derating coefficients are specified in ISO 16486-5. This document covers valves for pipes with a nominal outside diameter, dn, ≤400 mm.