ISO 16666-2025 PDF

ISO 16666-2025 PDF

Surface chemical analysis-Total reflection X-ray fluorescence-Principles and general requirements

$96.50 $193.00 -50%
Product Code: ISO 16666
Stock In Stock
Edition: 1.
Published: 11/2025
Number of Pages: 30
File Size: 1 file, 2 Bytes

Available Options

Product Description

Surface chemical analysis — Total reflection X-ray fluorescence — Principles and general requirements

Introduction: Through general technical developments, total reflection X‑ray fluorescence analysis (TXRF) has been developed into a robust independent physical method of instrumental analytical chemistry. TXRF is a distinct multi‑element micro‑method and a method of surface analysis. It is used for the simultaneous qualitative detection of the elements and quantification of the element masses. Notably, only small quantities of material are used for the analysis to benefit from all the advantages inherent to the procedure and thus to achieve correct analysis values. TXRF is used alongside other atomic spectroscopic methods, such as atomic absorption spectrometry (AAS) or inductively coupled plasma-based techniques (ICP‑AES and ICP‑MS) that are also established in the field of element analysis. In addition, TXRF is used in surface analysis and complements techniques such as Auger electron spectroscopy (AES), Rutherford backscattering spectrometry (RBS) or secondary ion mass spectrometry (SIMS). The rapid and in part non-destructive measurement process of a TXRF configuration allows screening or qualitative analysis of unknown flat, film-like and particulate samples and is therefore a valuable addition to other analytical techniques. The main difference between TXRF and conventional X‑ray fluorescence spectrometry (XRF) is the efficient way to excite the material to be examined to fluoresce which is achieved by a special geometrical arrangement in the spectrometer. The spectral background is

Scope: The document provides the physical principles and specifies instrumental requirements for total reflection X‑ray fluorescence analysis (TXRF) spectrometers. This document specifies general procedures for calibration, method development and verification of TXRF measurements and quality control. The document describes measurements with TXRF conditions having a fixed glancing angle below the critical angle of total reflection and considerably enhanced excitation radiation intensity. Although certain definitions of grazing incidence geometry are shown for clarification, this document is not applicable to measurement setups working under such conditions.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16666-2025 PDF

ISO 16666-2025 PDF

$96.50 $193.00