Cosmetics — Analytical methods — Development of a global approach for validation of quantitative analytical methods
Introduction: The purpose of this document is to propose a characterization protocol for the validation of a quantitative analysis method in the cosmetic field and thus responds to the requirements of ISO/IEC 17025, i.e. using the performance goals as a basis. The theoretical principles of this approach can be found in Reference [1]. This document is based on the French Standard NF V 03-110[2]. Analytical methods for analyses of cosmetics need to be validated. Validation has been long considered as a process consisting in individually verifying several different criteria, i.e. selectivity, repeatability, linearity, trueness, etc. The global approach, as proposed since 2003[1], is based on the total error concept and the term ‘’global” means that only a single criterion should be checked to validate a method: the agreement between a future experimental result and the true value. This approach has already been applied in the domains of pharmacy[1],[9], agricultural chemistry[2], and is in agreement with quality assurance guidelines such as GLP or ISO/IEC 17025. This validation process applies generally to already developed methods and includes evaluations of the following criteria: specificity/selectivity, precision, trueness, linearity range, LOD/LOQ, stability, ruggedness. The large number of cosmetic products and the variety of matrices present a challenge for an analytical laboratory requiring that standardized methods to be adapted for each type of samples. Additional difficulties are l
Scope: This document defines a global approach for the validation of a quantitative analytical method, based on the construction and interpretation of an accuracy profile, and specifies its characterization procedure. This procedure is particularly applicable for internal validation in a cosmetic testing laboratory, but its scope can be extended to the interpretation of data collected for an interlaboratory study designed according to the recommendations of the ISO 5725-1. It does not apply to microbiological trials. The present approach is particularly suited to handle the wide diversity of matrices in cosmetics. This document only applies to already fully-developed and finalized methods for which selectivity/ specificity have already been studied and the scope of the method to be validated has already been defined, in terms of matrix types and measurand (for example analyte) concentrations.