ISO TR 24679-4-2017 PDF

ISO TR 24679-4-2017 PDF

Fire safety engineering - Performance of structures in fire - Part 4: Example of a fifteen-storey steelframed office building

$129.00 $258.00 -50%
Product Code: ISO TR 24679-4
Stock In Stock
Edition: 1.
Published: 08/2017
Number of Pages: 56
File Size: 1 file, 2 Bytes

Available Options

Product Description

Fire safety engineering - Performance of structures in fire - Part 4: Example of a fifteen-storey steelframed office building

Introduction: This document is an example of the application of ISO 24679-1, prepared in the format of ISO 24679-1. It includes only those subclauses of ISO 24679-1 that describe the steps of the methodology for assessing the performance of structures in fire. It preserves the numbering of subclauses in ISO 24679-1 and so omits numbered subclauses for which there is no text or information relevant to this example. This example is intended to illustrate the implementation of the steps of the fire resistance assessment, as defined in ISO 24679-1. Only steps that are considered to be relevant to this example are well-detailed in this document. The technical contents are based on the performance based verification methods for fire resistance in the Building Standards Law of Japan, but were slightly modified for simplicity and compatibility with ISO 24679-1. © ISO 2017 – All rights reserved

Scope: This document provides a fire engineering application relative to the fire resistance assessment of a fifteen-storey steel framed building following the methodology given in ISO 24679-1. This document describes the adopted process which follows the same step by step procedure as that provided in ISO 24679-1. The annexes of this document present the detailed assessment results obtained for the most severe fire scenarios on the basis of the outcome of this specific fire safety engineering procedure for the building. The fire safety engineering applied in this example to the office building with respect to its fire resistance considers specific design fire scenarios as well as the corresponding fire development. It takes into account fully-developed compartment fires. In realistic situations, activation of fire suppression systems and/or intervention of fire brigade are expected, but their beneficial effects are not taken into account. It should be noted that these severe fire scenarios have been selected for fire resistance purposes. Global structural behaviour is not explicitly considered, but implicitly included in the calculation formulae. Since the building of the example is located in a seismic region, principal structural elements are rigidly connected to each other. Load redistribution from heated elements to cold surrounding elements exists, but it's not taken into account in the design calculations. By this approach, design is conservative, while the process of safety checking is greatly simplified and clear. As a result, all the calculations were carried out by explicit algebraic formulae.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 24679-4-2017 PDF

ISO TR 24679-4-2017 PDF

$129.00 $258.00