ISO TR 5168-1998 PDF

ISO TR 5168-1998 PDF

Measurement of Fluid Flow - Evaluation of Uncertainties

$60.00 $120.00 -50%
Product Code: ISO TR 5168
Stock In Stock
Edition: 1ST
Published: 04/01/1998
Number of Pages: 76
File Size: 1 file, 542 Bytes

Available Options

Product Description

ENGLISH * W/D S/S BY ISO 5168 Whenever a measurement of flowrate (discharge) is made, the value obtained from the experimental data is simply the best possible estimate of the true flowrate. In practice, the true flowrate may be slightly greater or less than this value. This Technical Report details step-by-step procedures for the evaluation of uncertainties in individual flow measurements arising from both random and systematic error sources and for the propagation of component uncertainties into the uncertainty of the test results. These procedures enable the following processes to be carried out: a) estimation of the accuracy of results derived from flowrate measurement; b) selection of a proper measuring method and devices to achieve a required level of accuracy of flowrate measurement; c) comparison of the results of measurement; d) identification of the sources of errors contributing to a total uncertainty; e) refinement of the results of measurement as data accumulate. NOTE — It is assumed that the measurement process is carefully controlled and that all calibration corrections have been applied. This Technical Report describes the calculations required in order to arrive at an estimate of the interval within which the true value of the flowrate may be expected to lie. The principle of these calculations is applicable to any flow measurement method, whether the flow is in an open channel or in a closed conduit. NOTE — Although this Technical Report has been drafted taking mainly into account the sources of error due to the instrumentation, it should be emphasized that the errors due to the flow itself (velocity distribution, turbulence, etc.) and to its effect on the method and on the response of the instrument can be of great importance with certain methods of flow measurement (see 5.7). Where a particular device or technique is used, some simplifications may be possible or special reference may have to be made to specific sources of error not identified in this Technical Report. Therefore reference should be made to the “Uncertainty of measurement” clause of the appropriate International Standard dealing with that device or technique.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 5168-1998 PDF

ISO TR 5168-1998 PDF

$60.00 $120.00