SAME AS IEC 62446-2 This part of IEC 62446 defines the information and documentation required to be handed over to a customer following the installation of a grid connected PV system. It also describes the commissioning tests, inspection criteria and documentation expected to verify the safe installation and correct operation of the system. It can also be used for periodic retesting. This part of IEC 62446 is written for grid connected PV systems that do not utilize energy storage (e.g. batteries) or hybrid systems. This part of IEC 62446 is for use by system designers and installers of grid connected solar PV systems as a template to provide effective documentation to a customer. By detailing the expected commissioning tests and inspection criteria, it is also intended to assist in the verification/inspection of a grid connected PV system after installation and for subsequent re-inspection, maintenance or modifications. This part of IEC 62446 defines the different test regimes expected for different solar PV system types to ensure that the test regime applied is appropriate to the scale, type and complexity of the system in question. NOTE This part of IEC 62446 does not address CPV (concentrating PV) systems, however many of the parts may apply. This Part 2 of IEC 62446 describes basic preventive, corrective, and performance related maintenance requirements and recommendations for grid-connected PV systems. The maintenance procedures cover: • Basic maintenance of the system components and connections for reliability, safety and fire prevention • Measures for corrective maintenance and troubleshooting • Worker safety This document also addresses maintenance activities for maximizing anticipated performance such as module cleaning and upkeep of vegetation. Special considerations unique to rooftop or ground-mounted systems are summarized. This document does not cover off-grid systems or systems that include batteries or other energy storage technologies; however, parts may be applicable to the PV circuits of those systems. This document also does not cover maintenance of medium and high voltage a.c. equipment that are sometimes integral to larger scale systems, as those requirements are not specific to PV systems. Maintenance of PV systems is often lumped into the catch-all term operations and maintenance (O&M). This document does not address business or management operational processes (e.g. forecasting, utility pricing incentives, etc.) or other considerations driven by factors outside of basic system working condition, safety and performance. The confirmation of a system’s compliance with the appropriate design and installation standards is covered in Part 1 and takes place during initial project commissioning. The objectives of this document are to: • Identify a baseline set of maintenance requirements which may differ by system type (residential, commercial, utility scale), owner, or financing requirements. • Identify additional maintenance steps that are recommended or optional. • Identify factors to be used to determine appropriate maintenance intervals. • Ensure that remote diagnostic methods are allowed as means for periodic verification, problem identification and early failure detection. • Ensure that alternate means of achieving maintenance related requirements are allowed to accommodate for innovation, manufacturer specific methods, evolving customer requirements, etc.